1. PREFACE

This service manual provides various service information, including the mechanical and electrical parts, etc. This room air conditioner was manufactured and assembled under a strict quality control system.

The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 FEATURES

‡DESIGNED FOR COOLING ONLY

‡BUILT-IN ADJUSTABLE THERMOSTAT

‡WASHABLE ONE-TOUCH FILTER

‡COMPACT SIZE

1.2 SPECIFICATIONS

1.2-2 SPECIFICATIONS

MODELS

CP05N10A

ITEMS

 

COOLING CAPACITY (BTU/h)

5,450

POWER SUPPLY (Phase, V, Hz)

1ø, 115V, 60HZ

 

 

INPUT (W)

510

 

 

OPERATING CURRENT (AMP.)

4.8

 

 

REFRIGERANT CONTROL

CAPILLARY TUBE

 

 

REFRIGERANT CHARGE (R410A)

280g (9.9 oz)

 

 

INSIDE FAN

TURBO FAN

 

 

OUTSIDE FAN

PROPELLER FAN WITH SLINGER RING

 

 

AIR DISCHARGE

2-WAY (RIGHT AND LEFT)

 

 

CHASSIS

TOP-DOWN

 

 

PROTECTOR

‡OVERLOAD PROTECTOR FOR COMPRESSOR

‡,17(51$/3ROTECTOR FOR FAN MOTOR

 

 

 

TEMPERATURE CONTROL

THERMISTOR

 

 

FAN MOTOR

4 POLES,21W

 

 

—2—

Page 3
Image 3
Friedrich CP05N10A manual Preface