2.3.6 POWER CORD

1.Disconnect the unit from source of power.

2.Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove a screw that secures control panel to base pan. (Refer to Section 2.1.3)

5.Pulls the control board toward you.

6.Disconnect the 2 receptacles and remove the grounding screw.

7.Remove a screw securing the clip with cord to the control panel.

8.Pull the power cord.

9.Re-install by referring to procedures above.

2.4 REFRIGERANT CYCLE

2.4.1 CONDENSER

1.Remove the cabinet. (Refer to Section 2.1.2)

2.Discharge the refrigerant by using a refrigerant recovery system.

3.Remove the air guide. (Refer to Section 2.2.1)

4.Remove 2 screws which fasten the condenser.

5.After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.

6.Remove the condenser.

7.Re-install by referring to the procedures above.

Figure 18

Figure19

—8—

Page 9
Image 9
Friedrich CP05N10A manual Refrigerant Cycle, Power Cord, Condenser