Master Lock MGR2900A, MGR4500I, MGR6000I Operation, General Information, Using Receptacle

Models: MGR2900A, MGR4500I, MGR6000I

1 24
Download 24 pages 22.04 Kb
Page 10
Image 10
OPERATION

R

PORTABLE GASOLINE GENERATORS

OPERATION

GENERAL INFORMATION

This generator is not large enough to power your entire home. Do not connect generator to any existing electrical circuits. Plug items directly into generator receptacles. Do not exceed amperage rating of receptacles. Only use grounded cords.

GENERAL INFORMATION DANGER: Use only in well- vented areas. Make sure area has plenty of free-moving, fresh, outside air. Never run generator in an enclosed or confined area. Never run generator inside oc- cupied building. Engine exhaust contains poisonous carbon monoxide gas. Overexposure will cause loss of consciousness and will lead to death.

USING RECEPTACLE DANGER: Never connect gen- erator to any existing electrical circuits. The generator output will back-feed into the utility power line. This may electrocute a power company line repair person.Also, if generator is powering electrical

USING RECEPTACLE

Note: Do not exceed amperage rating of receptacles. Exceeding rating will trip re- ceptacle circuit breaker.

Use receptacles properly. Improper use could damage generator. Use only grounded extension cords. Power only grounded or double-insulated items. Do not overload receptacles. All generators (except model MGR2900A) have the following receptacles (see Figure 8):

120V, 15-amp GFCI duplex receptacle

120V, 30-amp twist-lock receptacle

120/240V, 20 or 30-amp twist-lock receptacle

120V, 20-amp duplex receptacle

Model MGR2900A uses only the 120V,

120V, 15-Amp GFCI Duplex

120V, 20-Amp Duplex

120V, 30-Amp Twist-Lock

POWER CORD AND PLUG REQUIREMENTS

120V, 30-amp twist-lock receptacle

NEMA L5-30P plug

Three-wire, 30-amp cord

120/240V, 20 or 30-amp twist-lock receptacle

NEMA L14-20P (20-amp) or L14-30P (30-amp) plug

Four-wire, 20-amp or 30-amp cord

circuits, the chance of an electri- cal fire exists.

Note: We supply the engine owner’s manual with generator. Refer to that manual for ques- tions concerning engine operation.

120V

 

 

 

 

 

 

 

GFCI

 

 

 

 

 

 

 

 

 

 

 

 

120V

 

 

 

R

 

 

 

 

 

 

 

 

 

ES

 

 

 

 

 

 

 

120V

 

ST

 

 

 

 

 

 

TE

ET

 

 

 

 

 

 

TWISTLOCK

 

 

 

 

 

 

 

 

HO

 

 

 

 

 

 

 

 

 

UR

METER5

 

 

 

 

 

 

EN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

HOU0000000

 

 

 

 

 

 

 

RS

 

1/10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AU

 

 

 

 

VO

 

 

 

 

TO-

 

120

 

 

 

 

 

 

ID

LT

 

 

 

 

 

 

LE

ON

 

AG

 

 

 

 

 

 

LY

 

 

E

 

120/240V

OFF

 

 

 

 

 

 

 

120

 

 

ON

 

SELECTO

TWISTLOCK

 

 

 

 

+

 

 

 

 

 

 

 

 

R

240

 

R

 

 

 

 

 

 

 

 

 

ESET

 

 

 

 

 

 

 

 

 

 

RESET

 

 

 

 

 

 

 

 

 

 

 

RES

 

 

 

 

 

 

 

 

 

ET

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

ESET

120/240V, 20 or 30-Amp Twist-Lock

Figure 8 - Receptacle Locations

Figure 9 - Cord and Plug Configurations

10

118679

Page 10
Image 10
Master Lock MGR2900A, MGR4500I, MGR6000I Operation, General Information, Using Receptacle, Portable Gasoline Generators