Friedrich CP08E10, CP06E10 Troubleshooting Guide, Unit runs but poor cooling, Ineffective Cooling

Models: CP06E10 CP08E10

1 30
Download 30 pages 24.51 Kb
Page 20
Image 20
Troubleshooting Guide

Troubleshooting Guide

Unit runs but poor cooling.Ineffective CoolingTroubleshooting GuideManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

In general, possible trouble is classified in two kinds.

The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit runs but poor cooling.

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (heat exchanger)

Malfunction of fan.

Clogging of air filter.

Obstruction at air outlet.

Remove obstruction.

Check clogging in refrigera- tion circuit.

Repair clogging in refrigeration circuit.

Check outdoor coil (heat exchanger) and fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air; 44~50°F (7~10°C)

Check heat load increase.

Clean condenser.

Not on separate circuit

Check inside gas pressure.

Adjust refrigerant charge.

Malfunction of compressor.

Replacement of compressor.

Service Manual 20

Page 20
Image 20
Friedrich CP08E10, CP06E10 manual Troubleshooting Guide, Unit runs but poor cooling, Ineffective Cooling