Friedrich CP06E10, CP08E10 manual 23Room Air Conditioner, Troubleshooting Guide, Possible Trouble

Models: CP06E10 CP08E10

1 30
Download 30 pages 24.51 Kb
Page 23
Image 23
23Room Air Conditioner

Troubleshooting Guide

Possible Trouble 2

• The compressor does not operate.

Is Temp.

setting set lower than Room NO Temp.-0.5°C?

YES

• Set the Temp. setting to lower Temp.

Is the voltage No.10

NO

 

of IC01M 0V?

 

YES

Check the RY-COMP.

Check the wiring Diagram.

 

Is the voltage N0.7 of

 

NO

 

 

 

 

IC01M DC 5V?

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

• Exchange IC01M.

 

 

 

 

 

 

 

 

 

 

 

 

Is the Unit for 3 minutes

delay?

YES

• Wait 3 Minutes

Exchange MAIN P.W.B Ass'y.

NO

Possible Trouble 3

• The compressor always operate.

 

 

Is the wire connection of

RY-COMP all right?

YES

• Check the RY-COMP.

Possible Trouble 4

NO

• Fan does not operate.

Connect LEAD Wire to Manual background RY-COMP again.

Is the voltage NO.1 or 4

NO

of IC01M DC 5V?

 

 

YES

 

 

 

Is the voltage NO.13 or 16

NO

 

of IC01M 0V?

 

YES

Check the RY-Hi or RY-Lo.

Check the wiring diagram.

• Exchange IC01M.

• Exchange IC01M.