IMPORTANT POINTS ON SERVICE OPERATING SAFETY

IMPORTANT POINTS ON SERVICE OPERATING SAFETY

Please follow these instructions carefully :

Please follow these instructions carefully : Unplug the unit to avoid any danger from electric shock before disassembling the unit for repair.

FLOW CHART FOR INSPECTING AND REPAIRING THE UNIT If there is any sound of the refrigerant circulating when in operation, avoid touching the cooling coils.

Manual background If you need to perform any welding or soldering, be sure you are in a well ventilated area.

Manual background Only a qualified professional should perform any welding on the unit.

Manual background When repairing the unit, the specifications listed in this manual must be strictly adhered to when replacing any components.

Manual background When replacing any electrical components they should be factory approved units.

Manual background Be sure that any electrical components are properly wired and in place.

FLOW CHART FOR INSPECTING AND REPAIRING THE UNIT

Electricity shutdown

Check fuses on

main switch

Check if air filter is

clogged

Capacitors are faulty

Dehumidifier doesn't work

Can not dehumidify

Compressor doesn't

work

Refrigerant is leaking

Maintain

&

repair system

Check if drain bucket

water level switch

is broken

Humidity sensor

is broken

Humidity setting on continuous operation

Over load protector is

faulty

Supply Nitrogen 15Kg/cm² from low pressure side and locate the leakage

Use oxygen acetylene and 5% silver

iron to fill cracks and holes

Pump vacuum for at

least 15 minutes

After filling with

refrigerant proceed to test run

- 1 -