Figure 37: Minimum Piping Requirements for Series 24 Tankless Heater Manifolds

 

Table IV Tankless Heater Ratings

 

 

Boiler

Number of T-4 Tankless Heaters

 

 

Installed

 

 

Model

1

2

3

4

 

 

 

24-03

6.75

---

---

---

 

24-04

7.5

---

---

---

 

24-05

7.5

---

---

---

 

24-06

7.5

15

---

---

 

24-07

7.5

15

---

---

Figure 38: Schematic Tankless Heater Piping

24-08

7.5

15

---

---

24-09

7.5

15

22.5

---

 

 

24-10

7.5

15

22.5

---

 

24-11

7.5

15

22.5

---

 

24-12

7.5

15

22.5

30

 

Notes:

 

 

 

 

1. Ratings are given in gallons per minute continuous flow of water heated from 40°F to 140°F with 200°F boiler water.

2. For tankless heater quantities less than maximum allowable, it is important that water heaters be centrally located in the boiler.

See Figure 8 for appropriate locations.

3. Tankless heater pressure drop is 5.5 PSI at

7.5 GPM.