APPENDIX B3 - Series 24 Boiler Circulator and Diverting Valve Selection Chart, 20°F & 40°F T,

Bell and Gossett

Series 24 Boiler Circulator Selection - Bell and Gossett (20°F

Differential)

 

IBR

 

 

Boiler Recirculation

Bell and Gossett Circulating Pump

 

 

 

3-Way

 

 

 

 

 

 

 

SIZE

GROSS

TOTAL

Pipe

 

 

 

 

 

 

 

Valve

 

 

 

 

OUTPUT

GPM

Size

Valve

 

 

 

 

 

 

 

 

 

 

(MBH)

 

 

Part

Model No.

Imp "

HP

RPM

 

 

 

Size

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24-03

342

35

2.0"

1.5" NPT

330852

PL-36 - 1.5"

Std.

1/6

3300

 

 

 

 

 

 

 

 

 

 

24-04

471

48

2.0"

1.5" NPT

330852

PL-75 - 2"

Std.

1/6

3400

 

 

 

 

 

 

 

 

 

 

24-05

634

65

2.0"

2" NPT

330853

PL-130 - 2"

Std.

**2/5

3200

 

 

 

 

 

 

 

 

 

 

24-06

797

81

2.5"

*2.5" Flange

330854

PL-130 - 2"

Std.

**2/5

3200

 

 

 

 

 

 

 

 

 

 

24-07

937

96

2.5"

*2.5" Flange

330854

PL-130 - 2"

Std.

**2/5

3200

 

 

 

 

 

 

 

 

 

 

24-08

1087

111

2.5"

*2.5" Flange

330854

Ser. 60, Mod. 610 - 2"

4"

**1/2

1750

 

 

 

 

 

 

 

 

 

 

24-09

1316

134

3.0"

2.5" Flange

330855

Ser. 60, Mod. 610 - 2"

4"

**1/2

1750

 

 

 

 

 

 

 

 

 

 

24-10

1505

153

3.0"

2.5" Flange

330855

Ser. 80, Mod. 3x3x7B

5"

**1

1750

 

 

 

 

 

 

 

 

 

 

24-11

1690

171

3.0"

2.5" Flange

330855

Ser. 80, Mod. 3x3x7B

5"

**1

1750

 

 

 

 

 

 

 

 

 

 

24-12

1852

190

4.0"

3.0" Flange

330856

Ser. 80, Mod. 3x3x7B

5"

**1

1750

 

 

 

 

 

 

 

 

 

 

*Model F165-50 2½" 3-way valve.

**Use Additional Relay for Single Phase Power. Use Motor Starter for 3 Phase Power.

Series 24 Boiler Circulator Selection - Bell and Gossett (40°F

Differential)

 

IBR

 

 

Boiler Recirculation

Bell and Gossett Circulating Pump

 

 

 

3-Way

 

 

 

 

 

 

 

SIZE

GROSS

TOTAL

Pipe

 

 

 

 

 

 

 

Valve

 

 

 

 

OUTPUT

GPM

Size

Valve

 

 

 

 

 

 

 

 

 

 

(MBH)

 

 

Part

Model No.

Imp "

HP

RPM

 

 

 

Size

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

24-03

342

17

1.5"

1.0" NPT

330850

NRF-33

Std.

1/15

2950

 

 

 

 

 

 

 

 

 

 

24-04

471

24

1.5"

1.25" NPT

330851

PL-36

Std.

1/6

3300

 

 

 

 

 

 

 

 

 

 

24-05

634

32

1.5"

1.5" NPT

330852

PL-36

Std.

1/6

3300

 

 

 

 

 

 

 

 

 

 

24-06

797

40

1.5"

1.5" NPT

330852

PL-45

Std.

1/6

3300

 

 

 

 

 

 

 

 

 

 

24-07

937

48

2.0"

2.0" NPT

330853

PL-75

Std.

1/6

3400

 

 

 

 

 

 

 

 

 

 

24-08

1087

56

2.0"

2.0" NPT

330853

PL-75

Std.

1/6

3400

 

 

 

 

 

 

 

 

 

 

24-09

1316

67

2.0"

2.0" NPT

330853

PL-130 - 2"

Std.

**2/5

3200

 

 

 

 

 

 

 

 

 

 

24-10

1505

76

2.5"

*2.5" Flange

330854

PL-130 - 2"

Std.

**2/5

3200

 

 

 

 

 

 

 

 

 

 

24-11

1690

86

2.5"

*2.5" Flange

330854

PL-130 - 2"

Std.

**2/5

3200

 

 

 

 

 

 

 

 

 

 

24-12

1852

95

2.5"

*2.5" Flange

330854

PL-130 - 2"

Std.

**2/5

3200

 

 

 

 

 

 

 

 

 

 

*Model F165-50 2½" 3-way valve.

**Use Additional Relay for Single Phase Power. Use Motor Starter for 3 Phase Power.

86

Page 86
Image 86
Crown Boiler 24-09, 24-11, 24-10, 24-08, 24-12, 24-06, 24-05, 24-03 Boiler Recirculation Bell and Gossett Circulating Pump Way