A6. Tankless Application Only with RTC – NO Building Heat; with and without storage tank (MECHANICAL)

80

NOTES:

1)Install the boiler as indicated above for systems where the boiler return temperatures may be less than 135F and heating DHW with a tankless coil.

2)The boiler circulator must be sized using the sizing charts found in Appendix B.

3)The return sensor, S1, shall be installed at the return of the boiler. The boiler circulator may be located anywhere within the recirculation loop.

4)The balancing valve in the boiler return line, V1, may be necessary in low head by-pass loop applications.

5)Domestic Hot Water must be tempered for safe usage. The tankless aquastat and/or a storage tank aquastat (A1) are normally closed switches. Circuit breaks on temperature rise.

6)Expansion tanks, air scoops and other components left out for clarity.

7)Observe all applicable plumbing and electrical codes.

This diagram is for reference only. The installer or designer is responsible for the proper selection and design of the system.

Page 80
Image 80
Crown Boiler 24-11, 24-10, 24-08, 24-12, 24-06, 24-05, 24-09, 24-03, 24-04, 24-07 installation instructions