Friedrich SH15L30 Specifications, Installation Information, OPERATING TEMPERATURE CODE T3B, HG-08

Models: SH20L30 SH15L30

1 4
Download 4 pages 14.45 Kb
Page 4
Image 4
Specifications

Specifications

 

 

 

 

 

Energy Efficiency

Moisture

Air Direction

Room Side Air

 

Cooling Capacity

Electrical Characteristics (60 Hertz)

Ratio AHAM

Removal

Controls

Circulation

Model

(BTU/Hr.- AHAM)

Volts Rated

Amps AHAM

Watts

EER

(Pints/ Hr.)

 

CFM

SH15L30

15000/15000

230/208

7.9/8.7

1765/1765

8.5/8.5

4.0

8-way

375

SH20L30

19800/19500

230/208

10.0/10.9

2200/2167

9.0/9.0

5.7

8-way

375

Installation Information

 

 

 

 

 

 

 

 

 

 

 

Circuit Rating

 

 

 

 

 

 

 

 

 

Window Width

Thru-The-Wall Finished

Breaker or

 

Weight

 

 

 

Dimensions (Inches)

 

 

(Inches)

Hole (Inches)

T - D Fuse

 

(Lbs.)

 

 

 

 

 

Minimum

Minimum

 

 

 

 

 

 

 

 

 

 

Depth

Depth Hood

Extension

Extension

 

 

 

 

 

 

 

Model

Height

Width

Overall

to Louvers

Into Room

Outside

Min.

Max.

Height

Width

Volts - Amps

Net

Shipping

SH15L30

15 15/16

25 15/16

27 3/8

9 3/16

3 1/16

16 15/16

27 7/8

42

16 3/16

26 3/16

250V - 15A

140

152

SH20L30

17 15/16

25 15/16

27 3/8

9 3/16

3 1/16

16 15/16

27 7/8

42

18 3/16

26 3/16

250V - 15A

166

179

Due to continuing engineering research and technology, specifications are subject to change without notice. Manufactured under U.S. Design Patent DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. MAXIMUM TEMPERATURE RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D.

OPERATING TEMPERATURE CODE T3B

Friedrich Air Conditioning Co. P.O. Box 1540 San Antonio, TX 78295-1540 (800) 541-6645 fax (210) 357-4480 www.friedrich.com

HG-08

Printed in USA