Friedrich SV08, SV10, SV12 manual Electrical Parts, Overload Protector, Compressor

Models: SV10 SV08 SV12

1 27
Download 27 pages 17.78 Kb
Page 7
Image 7

2.2.3 SHROUD

1.Remove the fan. (Refer to section 2.2.2)

2.Remove the shroud. (See Figure 8)

3.Re-install the components by referring to the removal procedure, above.

2.3 ELECTRICAL PARTS

2.3.1 OVERLOAD PROTECTOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the nut which fastens the terminal cover.

3.Remove the terminal cover. (See Figure 9)

4.Remove all the leads from the overload protector.

5.Remove the overload protector.

6.Re-install the components by referring to the removal procedure, above.

2.3.2 COMPRESSOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Discharge the refrigerant system using a FreonTM Recovery System.

If there is no valve to attach the recovery system to install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

3.Remove the overload protector. (Refer to section 2.3.1)

4.After purging the unit completely, unbraze the suction and discharge tubes at the compressor connections.

5.Remove the 3 nuts and the 3 washers which fasten the compressor to the base pan.

6.Remove the compressor. (See Figure 10)

7.Re-install the components by referring to the removal procedure, above.

Figure 8

Figure 9

Figure 10

— 7—

Page 7
Image 7
Friedrich SV08, SV10, SV12 manual Electrical Parts, Overload Protector, Compressor