Friedrich Thru-the-Wall Air Conditioners Sleeve/Chassis Dimensions, 27” Sleeve Exterior Grilles

Models: Thru-the-Wall Air Conditioners

1 6
Download 6 pages 32.02 Kb
Page 4
Image 4
27” Sleeve Exterior Grilles

27” Sleeve Exterior Grilles

CORRECT Vertical Louvers

WSC Sleeve

Standard Grille - Ships with sleeve

IMPORTANT:

Operating the air conditioner with incorrect rear grille or without Baffle Adapter Kit (on 19 3/4” deep sleeve) will recirculate discharge air and cause compressor overload to trip.

WSC Sleeve

Optional Architectural Grille- AG

INCORRECT Horizontal Louvers

Installation Accessories (27” sleeve models only)

DK / Drain Kit

Installed at the back of the unit and allows for attachment to permanent condensate disposal system, if disposal is necessary or desired.

SB / Sub Base

Used as a base for the unit when it is desired to place the cord and receptacle within the installation, or simply as a base for the unit when mounted low in the wall.

IDK / Internal Drain Kit

New construction applications where a condensate drain system has been built into the wall interior.

BAK / Baffle Adapter Kit

Necessary when installing in a sleeve deeper than 16 3/4" deep, such as Fedders B sleeve (19 3/4" deep).

16 3/4"

WSC Sleeve Fedders B Installation Accessories (27” sleeve models only) 19 3/4”

26” Sleeve Exterior Grilles

USC Sleeve

Sleeve shown with

Standard Grille

Replacement Grille
STANDARD GRILLE – Ships with USC sleeve

Expanded aluminum grille designed for use with USC sleeve.

REPLACEMENT GRILLE – Ships with US/UE chassis

High-tech plastic for use on existing sleeves without any grille.

IMPORTANT:

When installing into an existing sleeve, consult Installation Section of your Installation/Operation Manual to determine whether or not the grille needs to be replaced and/or a baffle adapter should be used.

Sleeve/Chassis Dimensions

 

 

 

 

Depth

Minimum

Minimum

 

Thru-the-wall

 

 

 

 

with

Extension

Extension

 

Finished Hole
Model

Height

Width

Depth

Front

Into Room

Outside

Height

Width

Max. Depth

WALLMASTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WSC Sleeve

16 3/4"

27"

16 3/4"

23"

7 1/2"

9/16"

17 1/4"

27 1/4"

15 5/16"

Chassis

15 3/4"

26 1/2"

21"

22”

UNI-FIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USC Sleeve

15 1/2"

25 7/8"

16 3/4"

20 1/2"

1/2"

15 3/4"

26 1/8"

16 1/4"

IMPORTANT:

US= 3 3/8”, UE= 2 7/8

US Chassis

14 3/8"

24"

20 1/8"

3 3/4"

 

UE Chassis

14 3/8"

24 5/8"

19 5/8"

3 1/2"

US chassis w/front fully installed into USC sleeve extends into room 3 3/8”. UE chassis w/front fully installed into USC sleeve extends into room 2 7/8”.

IMPORTANT: Sleeves are sold and shipped separately to accommodate new construction and replacement requirements

Page 4
Image 4
Friedrich Thru-the-Wall Air Conditioners Sleeve/Chassis Dimensions, 27” Sleeve Exterior Grilles, DK / Drain Kit, 16 3/4