CONTENTS

1. PREFACE

 

1.1 SAFETY PRECAUTIONS

2

1.2 INSULATION RESISTANCE TEST

2

1.3 SPECIFICATIONS

3

1.4 FEATURES

4

1.5 CONTROL LOCATIONS

4

2. DISASSEMBLY INSTRUCTIONS

 

2.1 MECHANICAL PARTS

5

2.1.1 FRONT GRILLE

5

2.1.2 CABINET

5

2.1.3 CONTROL BOX

5

2.2 AIR HANDLING PARTS

6

2.2.1 ORIFICE, HEATER ASSY AND TURBO FAN

6

2.2.2 FAN

6

2.2.3 SHROUD

7

2.3 ELECTRICAL PARTS

7

2.3.1 MOTOR

7

2.3.2 COMPRESSOR

7

2.3.3 CAPACITOR

7

2.3.4 POWER CORD

8

2.3.5 THERMOSTAT

8

2.3.6 ROTARY SWITCH

8

2.4 REFRIGERATION CYCLE

9

2.4.1 CONDENSER

9

2.4.2 EVAPORATOR

9

2.4.3 CAPILLARY TUBE

9

3. TROUBLESHOOTING GUIDE

 

3.1 OUTSIDE DIMENSIONS

12

3.2 PIPING SYSTEM

12

3.3 TROUBLESHOOTING GUIDE

13

4. SCHEMATIC DIAGRAM

 

4.1 CIRCUIT DIAGRAM

18

5. EXPLODED VIEW

19

6. REPLACEMENT PARTS LIST

20

1. PREFACE

This SERVICE MANUAL provides various service information, including the mechanical and electrical parts etc. This room air conditioner was manufactured and assembled under a strict quality control system. The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 SAFETY PRECAUTIONS

1.When servicing the unit, set the ROTARY SWITCH or POWER SWITCH to OFF(O) and unplug the power cord.

2.Observe the original lead dress.

If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.

3.After servicing the unit, make an insulation resistance test to protect the customer from being exposed to shock hazards.

1.2 INSULATION RESISTANCE TEST

1.Unplug the power cord and connect a jumper between 2 pins (black and white).

2.The grounding conductor (green or green & yellow) is to be open.

3.Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part on the equipment at all the positions (except OFF or O) of the ROTARY SWITCH or

POWER SWITCH.

4.The value should be over 1MΩ .

—2—