Replacement of the refrigeration cycle.

1.When replacing the refrigeration cycle, be sure to discharge the refrigerant system using a FreonTM recovery System.

Install a valve for the recovery before venting the Freon. Remove the valve when finished.

2.After discharging the unit completely, remove the desired component, and unbrace the pinch-off tubes.

3.Solder service valves into the pinch-off tube ports, leaving the valves open.

4.Solder the pinch-off tubes with Service valves.

5.Evacuate as follows.

1)Connect the vacuum pump, as illustrated Fig. 18A.

2)Start the vacuum pump, slowly open manifold valves A and B with two full turns counterclockwise and leave the valves closed. The vacuum pump is now pulling through valves A and B up to valve C by means of the manifold and entire system.

CAUTION

If high vacuum equipment is used, just crack valves A and B for a few minutes, then open slowly with the two full turns counterclockwise. This will keep oil from foaming and being drawn into the vacuum pump.

3)Operate the vacuum pump for 20 to 30 minutes, until 600 microns of vacuum is obtained. Close valves A and B, and observe vacuum gauge for a few minutes. A rise in pressure would indicate a possible leak or moisture remaining in the system. With valves A and B closed, stop the vacuum pump.

4)Remove the hose from the vacuum pump and place it on the charging cylinder. See Fig. 18B. Open valve C.

Discharge the line at the manifold connection.

5)The system is now ready for final charging.

6.Recharge as follows :

1)Refrigeration cycle systems are charged from the High-side. If the total charge cannot be put in the High-side, the balance will be put in the suction line through the access valve which you installed as the system was opened.

2)Connect the charging cylinder as shown in Fig. 18B. With valve C open, discharge the hose at the manifold connection.

3)Open valve A and allow the proper charge to enter the system. Valve B is still closed.

4)If more charge is required, the high-side will not take it. Close valve A.

5)With the unit running, open valve B and add the balance of the charge.

a.Do not add the liquid refrigerant to the Low- side.

b.Watch the Low-side gauge; allow pressure to rise to 30 lbs.

c.Turn off valve B and allow pressure to drop.

d.Repeat steps B and C until the balance of the charge is in the system.

6)When satisfied the unit is operating correctly, use the pinch-off tool with the unit still running and clamp on to the pinch-off tube. Using a tube cutter, cut the pinch-off tube about 2 inches from the pinch-off tool. Use sil-fos solder and solder pinch-off tube closed. Turn off the unit, allow it to set for a while, and then test the leakage of the pinch-off connection.

—10—

Page 10
Image 10
Friedrich UE10, UE12, UE08 manual

UE08, UE10, UE12 specifications

Friedrich is a renowned name in the air conditioning industry, known for its commitment to quality and innovation. Among their popular models are the UE12, UE08, and UE10 air conditioning units, each designed to cater to different needs while maintaining high energy efficiency and performance standards.

The Friedrich UE12 is a robust unit that offers powerful cooling capabilities, making it suitable for medium to large rooms. With a cooling power of approximately 12,000 BTU, it effectively cools spaces without requiring excessive energy consumption. This model features a programmable thermostat, enabling users to set desired temperatures and automatically adjusting to maintain them. The UE12 also includes a remote control, allowing for easy adjustments from across the room. Its built-in dehumidifier function is an added bonus, keeping indoor humidity levels in check, which improves overall comfort and air quality.

The Friedrich UE08, with its 8,000 BTU cooling capacity, is perfect for smaller rooms or individual spaces. It strikes a balance between power and energy efficiency, making it ideal for those looking to cool a bedroom, home office, or den without incurring high electricity bills. The model features an easy-to-use control panel and a remote control, giving users flexibility in operating the unit from anywhere in the room. Additionally, its sleek design blends well with various interior styles, making it both a practical and aesthetically pleasing option.

Lastly, the Friedrich UE10 provides a cooling capacity of 10,000 BTU and is a versatile option suitable for medium-sized rooms. This model also includes advanced features like a multi-speed fan, allowing users to customize airflow according to their preferences. The UE10 is equipped with a programmable timer, allowing users to set it to turn on or off at specific times, thus maximizing energy efficiency. The unit's whisper-quiet operation and energy-saving capabilities position it as an excellent choice for those who value tranquility in their indoor environment.

Overall, the Friedrich UE series air conditioning units demonstrate a commitment to quality, efficiency, and user-friendly features. From the powerful cooling of the UE12 to the compact design of the UE08, these units cater to diverse cooling needs while ensuring optimal performance.