Friedrich ZQ05C10 manual Locations Of Controls, Safety Precautions, Insulation Resistance Test

Models: ZQ05C10

1 24
Download 24 pages 28.28 Kb
Page 4
Image 4
1.3 LOCATIONS OF CONTROLS

1.3 LOCATIONS OF CONTROLS

 

Operation

 

Off

: Turns air conditioner off.

 

 

Hi Fan

: High speed fan operation without

 

Hi

Hi

 

 

cooling.

 

Off

 

 

 

 

Fan O

Cool

Lo Fan

: Low speed fan operation without

 

 

 

Lo

O

Lo

 

cooling.

Fan

Cool

 

 

 

 

 

Hi Cool

: Cooling with high speed fan

 

 

 

 

operation.

 

Mode

 

Lo Cool

: Cooling with low speed fan

 

 

 

 

 

 

 

operation.

Thermostat

This automatically controls the temperature of the indoor air.

Turn the knob clockwise for greater cooling. Point the arrow counter-clockwise

for more moderate cooling.

WarmerCooler

Temperature

CAUTION : After switching the air conditioner from Cool to Off or Fan, wait at least 3 minutes before switching it back to Cool.

1.4 SAFETY PRECAUTIONS

1.When servicing, set the ROTARY SWITCH to Off and unplug the power cord.

2.Observe the original lead dress.

If a short circuit is found, replace all parts which have been overheated or damaged by the short cir- cuit.

3.After servicing, make an insulation resistance test to prevent the customer from being exposed to shock hazards.

1.5 INSULATION RESISTANCE TEST

1.Unplug the power cord and connect a jumper between 2 pins (black and white).

2.The grounding conductor (green or green and yel- low) is to be open.

3.Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part on the equipment at all position [except Off] of the ROTARY SWITCH.

4.The value should be over 1 M.

—4—

Page 4
Image 4
Friedrich ZQ05C10 manual Locations Of Controls, Safety Precautions, Insulation Resistance Test, Thermostat, Operation