Friedrich ZQ05B10, ZQ07B10 manual Piping System

Models: ZQ05B10 ZQ07B10

1 24
Download 24 pages 28.35 Kb
Page 13
Image 13
3.2 PIPING SYSTEM

3.2 PIPING SYSTEM

CAPILLARY

TUBE

CONDENSER COILS

FAN

MOTOR

TURBO FAN

EVAPORATOR COILS

Figure 22 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.

ROOM AIR CONDITIONER

CYCLE OF REFRIGERATION

EVAPORATOR COILS

CONDENSER COILS

COOLED

AIR

LIQUID

PRESSURE

DROP

 

SUCTION LINE

VAPOR INLET

HOT

COMPLETE LIQUID

 

COOL LOW PRESSURE VAPOR

BOIL OFF POINT

DISCHARGED

 

 

 

 

 

AIR

ROOM AIR HEAT LOAD

 

 

 

 

 

OUTSIDE COOLING

 

 

 

AIR FOR REFRIGERANT

 

 

 

PASS THROUGH

 

MOTOR

 

 

DISCHARGE

 

LINE

COMPRESSOR

NOT HIGH PRESSURE

VAPOR

OIL

 

 

LIQUID OUTLET

(LIQUID REFRIGERANT)

 

 

HIGH PRESSURE VAPOR

CAPILLARY TUBE

LIQUID REFRIGERANT

 

LOW PRESSURE VAPOR

Figure 22

— 13—

Page 13
Image 13
Friedrich ZQ05B10, ZQ07B10 manual Piping System