Frigidaire 137153700B Gas connection, to dryer, Electrical connection non-Canada 3-wire cord

Models: 137153700B

1 36
Download 36 pages 17.01 Kb
Page 10
Image 10
Gas connection

Gas connection

1.Remove the shipping cap from gas pipe at the rear of the dryer.

to dryer DO NOT connect the dryer to L.P. gas service without converting the gas valve. An L.P. conversion kit must be installed by a qualified gas technician.

2.Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from gas supply line to the 3/8 inch (0.96 cm) pipe located on the back of the dryer. Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm) reducer for the connection. Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections.

Manual

Flare

GAS FLOW

Shutoff

Flare

Union

Union

 

Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

Closed Shutoff Valve -

Nipple

Flexible

Inlet Pipe on

Open

Connector

Back of Dryer

All connections must be wrench-tightened

 - EXPLOSION HAZARD - NEVER test for gas leaks with an open flame. The supply line must be equipped with an ap- proved manual shutoff valve. This valve should be located in the same room as the dryer and should be in a location that allows ease of opening and closing. Do not block access to the gas shutoff valve.

3.Open the shutoff valve in the gas supply line to allow gas to flow through the pipe. Wait a few minutes for gas to move through the gas line.

Electrical connection (non-Canada) 3-wire cordto dryer

from

gas

supply

 

 

 

Shutoff Valve -

Open position

4.Check for gas system leaks with a manometer. If a manometer is not available, test all connections by brushing on a soapy water solution.

Manual backgroundManual backgroundManual backgroundManual backgroundManual background - EXPLOSION HAZARD - NEVER test for gas leaks with an open flame.

Electrical connection (non-Canada) 3-wire cord

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background - ELECTRICAL SHOCK HAZARD - Failure to disconnect power source before servicing could result in personal injury or even death.

1.Turn off power supply to outlet.

2.Remove the screw securing the terminal block access cover in the upper corner on the back of the dryer.

3.Install a UL-approved strain relief according to the power cord/ strain relief manufacturer’s instructions in the power cord entry hole below the access panel. At this time, the strain relief should be loosely in place.

4.Thread an UNPLUGGED, UL-approved, 30 amp. power cord, NEMA 10-30 type SRDT, through the strain relief.

5.Attach the power cord neutral (center wire) conductor to the SILVER colored center terminal on the terminal block. Tighten the screw securely.

6.Attach the remaining two power cord outer conductors to the outer, BRASS colored terminals on the terminal block. Tighten both screws securely.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background - ELECTRICAL SHOCK HAZARD - Do not make a sharp bend or crimp wiring/conductor at connections.

3-wire

30 AMP

 

NEMA 10-30

Neutral

receptacle

 

(center wire)

(NEMA type

 

 

10-30R)

 

 

 

 

Neutral

 

 

terminal

DO NOT remove

internal ground in a

3-wire system!

7.Follow manufacturer’s guidelines for firmly securing the strain relief and power cord.

8.Reinstall the terminal block cover.

Manual background If moving dryer from a 4-wire system and installing it in a 3-wire system, move the internal ground from the center terminal back to the GREEN screw next to the terminal block.

10

Page 10
Image 10