CLEANING AND CARE
Disconnect the power cord before cleaning or
leave the door open to deactivate the oven during cleaning.
CHARCOAL FILTERS
Charcoal Filters, which are attached with Hood Louver, are used for nonvented, recirculated installation. The filter should be changed every 6 to 12 months depending on use.
1.Disconnect power to the microwave oven at the circuit breaker panel or by unplugging.
2.Remove three Hood Louver Screws as in Figure 1.
3.Push in the upper tabs and pull the louver away from the unit.
4.Remove the charcoal filters from hood louver and replace new charcoal filters by piercing tabs into the holes in charcoal filters.
5.Carefully push the louver back into place and replace the screws removed at step 2.
Oven Light Cover
Hood Louver
Screws
Hood Louver
Figure 1
Upper Tab
Bottom Tab
Inside of Hood Louver
Charcoal Filters
MICROWAVE OVEN LIGHT
1.To replace light bulb, first disconnect power to the microwave oven at the circuit breaker panel or by unplugging.
2.Remove the louver per instructions under Charcoal Filter
3.Remove the light bulb and replace with a new 20 watt light bulb. DO NOT USE BULB LARGER THAN 20 WATTS.
4.Close the Oven Light Cover by carefully pushing into place. Push the louver back into place (engaging both the bottom and top tabs) and change to hood Louver Screws.
WORK/NIGHT LIGHT
1.To replace light bulbs, first disconnect power to the microwave oven at the circuit breaker panel or by unplugging.
2.To open Light Cover, remove the screw on the light cover. (See Figure 3.)
3.Replace the light bulbs with new 20 watt light bulbs. DO NOT USE BULBS LARGER THAN 20 WATTS.
4.Close the Light Cover and secure with screw removed at step 2.
BOTTOM VIEW
Light Bulbs | (Front of microwave oven) |
(Rear of microwave oven)
Figure 3 | Light Cover | Screw |
|
|
CAUTION
Light Cover may become very hot. Do not press glass when light is on.
Tabs
Figure 2
27