SERVICE CALL CHECK
Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the oven and close the door securely. Operate the oven for one minute at HIGH 100%.
A Does the oven light come on? | YES ____ | NO ____ | |
B | Does the cooling fan work? | YES ____ | NO ____ |
| (Put your hand over the left side of louver.) |
|
|
C | Is the water in the oven warm? | YES ____ | NO ____ |
If A is "NO", then you need to check light bulb. See page 27 for removal.
If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/ or circuit breaker. If they are functioning properly, CONTACT YOUR NEAREST ELECTROLUX AUTHORIZED SERVICER.
A microwave oven should never be serviced by a
NOTES
1.If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 25 and cancel.
2.If the oven is set for 40 minutes and over at 80, 90 or 100 percent power level, after the first 40 minutes the power level will automatically adjust itself to 70 percent power to avoid overcooking.
SPECIFICATIONS
AC Line Voltage: | Single phase 120V, 60Hz, AC only |
|
|
AC Power Required: | 1650 W 14.3 amps. |
|
|
Output Power*: | 1000 watts |
|
|
Frequency: | 2450 MHz |
|
|
Outside Dimensions (including handle): | 29 15/16”(W) x 17 1/16”(H) x 18 15/32”(D) |
|
|
Cavity Dimensions: | 22 1/2”(W) x 10 1/16”(H) x 14 31/32”(D) |
|
|
Microwave oven Capacity**: | 1.8 Cu.Ft. |
|
|
Weight: | Approx. (net) 61 lb, (gross) 73 lb |
|
|
Work/Night Light: | 2 bulbs 20w each (incandescent light bulbs) |
|
|
*The International Electrotechnical Commission’s standardized method for measuring output wattage. This test method is widely recognized.
**Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less.
In compliance with standards set by:
FCC | - Federal Communications Commission Authorized. | |
DHHS | - | Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J. |
| - | This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. |
28