30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Three Conductor Wire Connection to Range
If local codes permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord (see Figure 3):
1.Remove the screws from the access plate at the lower right end of the rear cover to expose range terminal connection block.
2.Using the nuts supplied in the literature package, connect the neutral of the copper power supply cord to the center
3.Replace the terminal cover and replace the screws.
Silver Colored Terminal
Red Wire
Terminal | Cord | |
Block | ||
Mounting | ||
| ||
| Plate | |
Black | Neutral | |
Wire | (White Wire) | |
| Grounding | |
| Strap |
A User Supplied |
| 1 1/8" (2.9 cm) Dia. | |
| Direct Connection | ||
| |||
To 240 V | Hole. Punch Out | ||
Be Installed at This | |||
Knockout for 1 3/8" | |||
Location. | Receptacle | ||
(3.5 cm) Dia. Cord | |||
|
| ||
| Figure 3 | Kit Hole. | |
|
|
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord (see Figure 4):
1.Remove the screws from the access plate at the lower right end of the rear cover to expose range terminal connection block.
2.Remove the grounding strap from the terminal block and from the appliance frame.
3.Using the nuts supplied with the literature package, connect the ground wire (green) of the copper power supply cord to the frame of the appliance with the ground screw, using the hole in the frame where the ground strap was removed (see Figure 4).
4.Connect the neutral of the copper power supply cord to the center
5.Replace the terminal cover and replace the screws.
Terminal Block | Silver Colored Terminal |
Red
Wire
Black Wire |
|
1 1/8" (2.9cm) |
|
Dia. Direct |
|
Connection |
|
Hole. Punch | Neutral |
Out Knockout | (White Wire) |
for 1 3/8" | Ground (Bare |
(3.5cm) Dia. | |
Cord Kit Hole. | Copper Wire) |
A User Supplied |
|
| |
Be Installed at This |
|
Location | To 240 V Receptacle |
NOTE: Be sure to remove the supplied grounding strap.
Figure 4
3