30" Warmer Drawer Specifications

30" Combination Installation

Built-In Microwave / Single Wall Oven / Warmer Drawer

30" Combination Installation Specifications

Always consult local and national electric codes.

(Refer to product-specific electrical specifications on this page.)

Minimum 23-5/8" deep cutout dimension is critical for proper combination installation, to ensure that each built-in product’s faceplate will fit flush against cabinet front.

Bases must be level and cabinet front must be square.

Minimum 4-1/2" required distance from bottom of Warmer Drawer cutout to floor.

Respect critical dimensions as noted for proper installation of built-In products.

Minimum 21" clearance needed for Wall Oven door depth when open.

30" Built-In Microwave Specifications

For built-in installation, microwave MUST be installed with optional 30" Trim Kit which includes Bottom Duct Assembly – shipped in separate box, ordered by individual part number.

Voltage Rating – 120V / 60 Hz / 15 or 20 Amps

Connected Load (kW Rating) @ 120 Volts = 1.7 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)

Amps @ 120 Volts = 14.3 Amps

Full oven base of solid plywood or similar material required, capable of supporting 100 Lbs.

Minimum 2-7/8" clearance required from bottom of Built-In Microwave cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap between both product faceplates.

30" Electric Single Wall Oven Specifications

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line.

For detailed electrical requirements, refer to model-specific product page and installation guide on web.

To support Wall Oven when using in combination with Warmer Drawer, two 3"-wide x 3/4"-thick planks must be installed as a base, capable of supporting 200 Lbs. Do NOT use full base, since planks are necessary to allow for proper air displacement.

30" Warmer Drawer Specifications

Voltage Rating – 120V / 450W / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.5 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)

Amps @ 120V = 3.8 Amps

Full base of solid plywood or similar material required, capable of supporting 100 Lbs.

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com

CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.caSpecifications subject to change.

MOSS24_EW_WD 30INST FR 06/11

© 2011 Electrolux Home Products, Inc.

Printed in the U.S.A.

Page 5
Image 5
Frigidaire FGMO205K manual Warmer Drawer Specifications, Combination Installation Specifications