10Installing the hood

10Installing the hood

Exhaust operation CAUTION

Danger of injury. The chimney skirts may have some sharp edges.

Air recirculation operationExhaust operation

During exhaust operation, the range hood removes air from a room. If other fire sources that require the surrounding air for combustion are being operated in the same room, (e.g. gas, oil or coal heaters), the oxygen they require is taken away. Thus flames could be suffocated and gas could leak out or the fumes could be drawn back into the room.

In order to guarantee a safe operation, there should be non-closable openings in doors, windows to ensure a fresh supply of combustion air. This will prevent the combustion fumes from being drawn back into the room.

When assessing the measures necessary, always take the entire ventilation system of the house into consideration.

Never secure the range hood to a ventilation duct, or a room or exhaust gas chimney! Do not let the air that is removed from the room be drawn into a duct where warm air is circulating. The extracted air should only be drawn outdoors through a separate ventilating duct that is only for the extractor hood.

When in extraction mode, air in the room is being removed by the range hood. Please make sure that proper ventilation measures are being observed. The range hood removes odors from room but not steam.

There shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).

The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).

Air recirculation operation

Recirculated air: Kitchen fumes are removed and after purification are fed back into the room through the upper ventilation openings.

The purification takes place via metallic anti- grease filter. No wall breakthrough is required for recirculated air operation.

GB

Installing range hood to the wall in recirculation mode

For the operation of the range hood with recirculation mode a recirculator, model no. FHWRKT60LS, needs to be obtained. Please call Frigidaire at 1.800.944.9044 to order this kit.

Follow steps 1 to 4 from Fixing range hood to the wall (with exhaust ducting) chapter.

To install the recirculator (7), use the template included in recirculation kit for proper position.

Place the recirculator (7) against the upper bracket

(4) by using the upper holes with upper bracket in the wall.

Fix the recirculator (7) to the wall with 2 sets of long screws (10) and wall plugs (11) (fig. Installing range hood to the wall in recirculation mode).

Attach the exhaust duct on the bottom of the recirculator (7).

Follow steps 5 to 6 from Fixing range hood to the wall (with exhaust ducting) sub-chapter.

fig.

Upper

Recirculator

 

 

bracket

 

Wall

 

 

 

Lower

 

 

screw holes

 

 

Lower bracket

fig.

 

 

Take out the grease filters and fit charcoal filters to two lateral sides of the motor blower. Assemble back the grease filters. (fig. Upper).