Frigidaire FRP77ETT3R Packaged Terminal Air Conditioner PTAC, Rearward Slope, PTAC Specifications

Models: FRP77ETT3R

1 5
Download 5 pages 11.46 Kb
Page 3
Image 3
Rearward Slope

Packaged Terminal Air Conditioner (PTAC)

FRP77ETT3R Air Conditioner / Electric Heater 

Rearward Slope

Wall Sleeve

Adapter

Front Panel

Chassis

1/4" Slope

Accessory

Outdoor Grille

Accessory

 

 

Wall Sleeve

Outside Wall

Inside Wall

 

Product Dimensions

 

Height

16"

Width

42"

Depth

13-13/16"

Max. Wall Thickness

13-13/16"

Wall Cutout Dimensions

 

Height

16-5/16"

Width

42-3/16"

 

 

Plug Type (NEMA)

7-20P

PTAC Specifications

Product Shipping Weight (approx.) – 123 Lbs.

An electrical supply with grounded three-prong receptacle is required. The power supply circuit must be installed in accordance with current edition of National Electrical Code (ANSI/NFPA 70)

and local codes & ordinances.

Voltage Rating – 265V / 60 Hz / 20 Amps

Amps @ 265V Volts = (Cool) 2.6 Amps / (Electric Heater) 11.32 Amps

Always consult local and national electric codes.

Recommended Circuit Breaker – 20 Amps

Unit equipped with 265V 3-wire power supply cord, NEMA plug type 7-20P, approximately 2.6' long.

In order for condensate water to drain properly inside the unit, the sleeve must be installed properly: Level from right to left with a slight 1/4" rearward pitch from the indoor side to the outdoor side as shown in the illustration above. Refer to the Installation Instructions on the web.

The drain kit listed on the Frigidaire® PTAC Accessories page can be used for an internal or external drain. This applies to new and replacement installation.

Replacement Installation

When replacing existing PTAC with new unit, refer to Product Installation Guide on web to identify existing wall-sleeve manufacturer and size compatibility. If proper installation and slope are suspect, then correct installation of Frigidaire® PTAC Sleeve options recommended.

For any sleeve retrofit application, be sure that the foam seals (factory-installed on the tube sheets) provide a good seal between the grille and the outdoor coil tube sheets. These foam seals provide a barrier that stops air from the inside mixing with air on the outside (known as air recirculation).

Using Frigidaire® wall sleeve with Non-Frigidaire grille requires installation of an Accessory Baffle Kit, which ensures a good seal between the unit and exterior grille to prevent air recirculation. Air recirculation is a large contributor to performance loss and premature damage to major components.

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

*See Frigidaire® PTAC accessories pages attached for optional accessories.

New Installation

For new installation, Frigidaire® PTAC Sleeves are available and recommended for proper installation. See accessories pages for sleeve options.*

Standard PTAC installation requires 13-13/16" maximum wall thickness, unless a wall sleeve is used.

If the PTAC unit protrudes more than 4", then it is suggested that it be

installed with a subbase. See accessories pages for subbase options.

USA 10200 David Taylor Drive Charlotte, NC 28262 1-866-942-1567 frigidaire.com

Specifications

CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-866-942-1567 frigidaire.ca

subject to change.

FRP77ETT3R 08/11

© 2011 Electrolux Home Products, Inc.

Printed in the U.S.A.