Frigidaire HV2730B Preparation, Mount The Unit, Cut Countertop Opening, Left Or Right Discharge

Models: HV2730B HV2736B

1 6
Download 6 pages 38.92 Kb
Page 3
Image 3
PREPARATION

PREPARATION

CUT COUNTERTOP OPENING

CHANGING BLOWER DISCHARGE (Optional)

The blower is shipped with its discharge facing DOWN. Follow these steps ONLY if:

the position of the blower discharge needs to be moved so ductwork does not interfere with floor joists, plumbing or wiring below.

it is necessary to rotate the blower discharge to the RIGHT or LEFT.

Place the unit on its back on a table or work surface.

DOWN DISCHARGE - MOVING BLOWER LEFT OR RIGHT

SHEET

BLOWER METAL

NUTSSCREW

CLAMP

CHANNEL

1. Loosen the 4 nuts and 2 clamp channels.

BOTTOM

FLANGE

2.Slide blower to desired position.

3.Use supplied cover plate to close open space (if any).

4.Tighten nuts to secure top of blower and use sheet metal screws through bottom flange to secure bottom of blower.

LEFT OR RIGHT DISCHARGE

BLOWER

NUT

1.Lay out and cut the cooktop cut-out far enough FORWARD so downdraft will fit behind it.

2.Set cooktop in place and slide it as far forward as possible. Center and square it with edges of countertop.

3.Place the plastic template against the back flange of the cooktop and center it. Trace around template to mark the downdraft opening.

4.Remove cooktop from countertop.

5.Cut downdraft opening. Be careful not to chip edges of countertop.

MOUNT THE UNIT

MOUNTING SCREWS

LEVELING BRACKET -

FLANGE FACING OUT

CLAMP CHANNEL

MOTOR

PLUG

SHEET

METAL

SCREW

LEVELING BRACKET - FLANGE FACING IN

COVER PLATE

1.Remove the 4 nuts and 2 clamp channels.

2.Carefully lift blower and disconnect motor plug if necessary. Reposition blower and RECONNECT MOTOR PLUG.

3.Use supplied cover plate to close open space (if any).

4.Replace clamp channels and use nuts to secure the blower in its new position.

5.Use sheet metal screws through bottom flange to secure bottom of blower.

1.Set downdraft into opening. Extend leveling brackets to floor of cabinet so downdraft sits straight. (Note: Leveling brackets can be removed and re-attached in other positions. Bottom flange may have to face inward in tight cabinet installations.)

2.Secure the downdraft to the countertop as follows: Hold the downdraft against the back of countertop cut-out and tighten- ing the 2 mounting screws (one on each end of unit) on underside of countertop. Use a wood shim between screw and underside of granite countertops.

3.Screw leveling brackets to bottom of cabinet. Tighten screws

3holding leveling bracket to unit on each side.

Page 3
Image 3
Frigidaire HV2730B Preparation, Mount The Unit, Cut Countertop Opening, Down Discharge - Moving Blower Left Or Right