Frigidaire RC30G60PS dimensions Gas Cooktop with Ventilation Unit, Rear Discharge, Down Discharge

Models: RC30G60PS

1 4
Download 4 pages 28.81 Kb
Page 3
Image 3
30" Gas Cooktop with Ventilation Unit

Built-In Downdraft Cooktop

RC30DG60PS 30" Gas

30"

Rear Discharge 13" max.

cabinet

depth

3 11/16"

18 15/16"

30"

Down Discharge 2113/32"

26 13/16"

30" min. for unprotected cabinet bottom 24" min.

for protected

cabinet bottom

18"

min.

Ventilation unit not shown beneath cooktop.

30" Gas Cooktop with Ventilation Unit

For ventilation unit ductwork preparation and installation planning information, refer to 30" Gas Cooktop Ductwork Preparation page.

Rear Discharge

Right Side View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17 13/16"

13/8" minimum flat distance from cutout edge

191/8"

24"

28"

9" min. to nearest combustible wall (each side of unit)

Down Discharge

Right Side View

 

 

 

 

23 3/8"

13/8" minimum flat distance from cutout edge

Built-In Cooktop Specifications

Cooktop Shipping Weight (approx.) – 89 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amps

For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.

Amps @ 120 Volts = 15

Always consult local and national electric and gas codes.

For detailed electrical and gas supply locations, refer to

30" Gas Cooktop (RC30DG60P) Ductwork Preparation page.

Locate cooktop between wall studs or floor joists so that ductwork may be installed properly.

Installing cooktop into pre-existing base cabinets may require modifications. Cabinets with drawers require drawers be removed and drawer fronts attached to cabinet face. Verify internal length and width of cabinet base because sides or back wall may need cut out and corner braces removed to accommodate unit.

Countertop opening MUST be cut based on dimensions shown, cut squarely with sides parallel to each other and with front and rear perpendicular to cabinet sides.

Pre-formed countertops with raised lip and radius at base of backsplash may not allow enough flat area for proper installation. Minimum 1-3/8" distance required from rear and front edge of cooktop cutout.

Provide adequate gas supply. Cooktop ships with 3/4" factory regulator.

LP Gas conversion kit supplied.

Overhead cabinetry should not exceed a 13" maximum depth.

Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than 36".

Allow 30" minimum clearance between top of cooktop platform and bottom of unprotected wood or metal overhead cabinet.

Allow 9" minimum required clearance from left edge and right edge of cooktop to nearest combustible wall on each side.

Ductwork Preparation

For ventilation unit ductwork preparation and planning information, refer to 30" Gas Cooktop (RC30DG60P) Ductwork Preparation page.

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

Optional Accessories

Granite Countertop Installation Kit – (PN # 903103-9010)

Accessories information available on the web at frigidaire.com

USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com

Specifications

CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca

subject to change.

RC30DG60P 07/13

© 2013 Electrolux Home Products, Inc.

Page 3
Image 3
Frigidaire RC30G60PS Gas Cooktop with Ventilation Unit, Rear Discharge, Down Discharge, Built-In Cooktop Specifications