RC30DG60PS 30" Gas
30" Gas Downdraft Cooktop –
Electrical / Gas Supply Location
Ductwork Preparation
Ventilation unit comes detached from cooktop.
To ensure proper installation, refer to 30" Gas Downdraft Cooktop Specifications page for planning information, and installation guide on web for complete installation details including countertop and cabinet requirements.
Ducting Options
On floor, through floor or through wall.
Cabinet | 51/2" | C |
| L | |
side wall |
| 31/4" |
Recomm. gas supply stub area
4"
4" 11"
Countertop
surface
Cabinet
side wall Electrical
Installation Note:
Locate 120 volt, 60 Hertz, properly grounded branch circuit protected by 15 amp circuit breaker or time delay fuse within shaded area shown.
Exhaust Outlet Locations –
Cut exhaust outlet hole in wall or floor based on desired installation. Exhaust duct MUST be located between wall studs or floor joists.
4 5/16"
Cutout |
|
|
center | Cutout |
|
| 8" | |
| center | |
|
| |
|
| 6" |
6" |
|
|
4 5/16" | 7 1/8" |
|
Bottom | Rear Wall |
Exhaust Outlet | Exhaust Outlet |
Built-In Cooktop Ductwork Preparation
•Ventilation unit comes detached from cooktop. To ensure proper installation, refer to 30" Gas Downdraft Cooktop Specifications page for planning information, and installation guide on web for complete installation details including countertop and cabinet requirements.
•Ducting Options – On floor, through floor or through wall.
•Ventilation Unit Discharge Options – Rear or down.
•Consider ductwork location and desired installation before cutting exhaust outlet hole in cabinet. For proper installation, cooktop exhaust duct MUST be located between wall studs or floor joists.
•Vent exhaust air outside only and NOT into any concealed space.
•Exhaust Duct Required – Galvanized or aluminum duct in 6" round or
•Local building code must be followed in specifying approved type and schedule of ALL duct used; always use appropriate roof or wall cap with damper.
•For maximum efficiency, use shortest, straightest duct run possible. Unit operates most efficiently with up to 100 equivalent feet of duct. (Refer to Calculating Duct Length Table in Product Installation Guide.)
•Flexible ducting is not recommended due to severely restricted airflow; if blower outlet and floor or wall duct location do NOT align, flexible METAL ducting can be used to adapt to offset.
•Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold. Cold weather installations should have additional backdraft damper installed.
Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 •
Accessories information available on the web at frigidaire.com
Specifications subject to change.