Frigidaire RC30G60PS Electrical / Gas Supply Location, Ducting Options, Exhaust Outlet Locations

Models: RC30G60PS

1 4
Download 4 pages 28.81 Kb
Page 4
Image 4
30" Gas Downdraft Cooktop –

Built-In Downdraft Cooktop

RC30DG60PS 30" Gas

30" Gas Downdraft Cooktop –

Electrical / Gas Supply Location

Ductwork Preparation

Ventilation unit comes detached from cooktop.

To ensure proper installation, refer to 30" Gas Downdraft Cooktop Specifications page for planning information, and installation guide on web for complete installation details including countertop and cabinet requirements.

Ducting Options

On floor, through floor or through wall.

Cabinet

51/2"

C

 

L

side wall

 

31/4"

Recomm. gas supply stub area

4" Electrical / Gas Supply Location

Ductwork PreparationDucting Options 4" 11"

Countertop

surface

Cabinet

side wall Electrical

Installation Note:

Locate 120 volt, 60 Hertz, properly grounded branch circuit protected by 15 amp circuit breaker or time delay fuse within shaded area shown.

Exhaust Outlet Locations –

Cut exhaust outlet hole in wall or floor based on desired installation. Exhaust duct MUST be located between wall studs or floor joists.

4 5/16"

Cutout

 

 

center

Cutout

 

 

8"

 

center

 

 

 

 

6"

6"

 

 

4 5/16"

7 1/8"

 

Bottom

Rear Wall

Exhaust Outlet

Exhaust Outlet

Built-In Cooktop Ductwork Preparation

Ventilation unit comes detached from cooktop. To ensure proper installation, refer to 30" Gas Downdraft Cooktop Specifications page for planning information, and installation guide on web for complete installation details including countertop and cabinet requirements.

Ducting Options – On floor, through floor or through wall.

Ventilation Unit Discharge Options – Rear or down.

Consider ductwork location and desired installation before cutting exhaust outlet hole in cabinet. For proper installation, cooktop exhaust duct MUST be located between wall studs or floor joists.

Vent exhaust air outside only and NOT into any concealed space.

Exhaust Duct Required – Galvanized or aluminum duct in 6" round or 3-1/4" x 10" rectangular, or combination of both. PVC should be used if installing under concrete slab.

Local building code must be followed in specifying approved type and schedule of ALL duct used; always use appropriate roof or wall cap with damper.

For maximum efficiency, use shortest, straightest duct run possible. Unit operates most efficiently with up to 100 equivalent feet of duct. (Refer to Calculating Duct Length Table in Product Installation Guide.)

Flexible ducting is not recommended due to severely restricted airflow; if blower outlet and floor or wall duct location do NOT align, flexible METAL ducting can be used to adapt to offset.

Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold. Cold weather installations should have additional backdraft damper installed.

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca

Accessories information available on the web at frigidaire.com

Specifications subject to change.

RC30DG60P 07/13

© 2013 Electrolux Home Products, Inc.

Page 4
Image 4
Frigidaire RC30G60PS Electrical / Gas Supply Location, Ducting Options, Exhaust Outlet Locations, Bottom, Rear Wall