●Check that the door gasket seals all around when the door is closed and that the door moves freely
●Move cover plate from one handle mould to the otherone
DOOR PANEL
The door panel can easily be mounted or changed. The
dimensions of the panel must be: |
|
Height | . . . . 722 mm |
Width | . . . . 504 mm |
Thickness | max 3.8 mm |
●Remove the door, see REPOSITIONING THE HINGES.
●Remove the lower trim moulding and then withdraw the panel by sliding it downwards.
●Fit the new panel in place and slide it up as far as possi- ble.
●Fit the trim moulding back in place.
INSTALLATION
The room should have a capacity (length x width x height) of at least 20 m3 and have a window (which can be opened) or a door to the outside.
It is important that the refrigerator is not subject to radiation of heat from a stove etc.
For best performance also at high ambient temperatures there must be a free air circulation over the cooling unit at the rear of the refrigerator.
The refrigerator is designed for a
LP GAS CONNECTION
CAUTION! CHECK THAT THE GAS SUPPLIED TO THE REFRIGERATOR IS AT THE CORRECT PRESSURE. SEE THE REDUCING VALVE ON THE LP GAS CON- TAINER.
The refrigerator is designed for operation on LP gas, the pressure of which must be 28 mbar for Butane and 37 mbar for Propane. Check that this is stated on the data plate.
The refrigerator is not designed for operation on town gas or natural gas.
The gas installation should only be carried out by an autho- rized gas fitter.
The gas supply pipe should be connected to the gas inlet pipe on the right hand side of the gas control valve by means of a suitable threaded coupling.
In making the connection to the refrigerator, a union gas cock of an approved
ELECTRICAL CONNECTION
The electrical installation must be carried out in a proper and durable manner, taking into account all relevant regu- lations and codes of practice. For mains voltage operation, it is important that the circuit to and in the caravan is effec- tively earthed.
ALL MAINS VOLTAGE WIRING IN THE CARAVAN MUST BE INSTALLED IN ACCORDANCE WITH CURRENT I.E.E. REGULATIONS INCLUDING THE USE OF AN OUTLET AND COUPLER TO BS4343/- CEE17.
For connection to a 230 V electricity supply, the refrigerator has a
IMPORTANT: The wires in the mains lead of this appliance are coloured in accordance with the following code:
GREEN-AND-YELLOW = EARTH
BLUE = NEUTRAL
BROWN = LIVE
As the colours of the wires may not correspond with the coloured markings identifying the terminals in your plug, in the United Kingdom, proceed as follows:
The wire which is coloured
the letter E or by the earth symbol , or coloured green or
The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured black.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured red.
WARNING - THIS APPLIANCE MUST BE EARTHED.
In the United Kingdom, the plug or circuit to the
Plug the 230 V refrigerator power cord into an easily acces- sible wall socket.
Electrical leads must be routed and secured so that they cannot come into contact with hot or sharp parts of the refrigerator.
The notations in the wiring diagramme (fig. 2) are: G. Electric thermostat
H. Heating element, 230 V
I. Switch for 230 V operation