Frymaster 1824E manual Unplug all power cords

Models: 1824E

1 42
Download 42 pages 47.8 Kb
Page 8
Image 8
Manual background

1.10Replace Temperature Sensor and High-Limit Thermostat Probes

1.Unplug all power cords.

2.Drain the cooking oil from the frypot and leave the drain open.

3.Lift up and remove the element guardplate.

4.Remove the two screws from the bottom of the faceplate cover.

Element Guardplate

5.After removing screws, gently tilt up and lower faceplate. Note that when lowering the faceplate, the door will lower and swing out to be set aside as well.

6.Remove the six screws from the top access cover.

7.After removing screws, remove panel by lowering down the front of the frame and pushing in on the high-limit reset switch so that it will slide down. To make reassembly easier, push out the black grommet and snap back in when completely reassembled.

Underside of

Top access cover

faceplate has

has six screws.

two screws.

 

8.Remove the screws securing the probe bracket to the elements and remove the probe bracket.

9.Remove the metal clamps securing the probe to the elements.

10.Disconnect the wire plug containing the probe wiring.

11.Using an open end wrench, loosen the temperature probe. Thread the probe wire through the hole and remove the probe.

Remove the screws from probe brackets.

1-5