Frymaster™®
H55
26.70
ELECTRICAL SUPPLY FOR (4) BATTERY
(678)
ELECTRICAL SUPPLY FOR (2) BATTERY | 22.00 | |
(559) | ||
|
14.35
ELECTRICAL SUPPLY FOR (3) BATTERY (365)
6.38
2.25 (162)
(57)
34.2531.50
(869)(799)
W/BASKET W/O BASKET 27
LIFTER LIFTER (675)
REAR GAS CONNECTION ON FRYERS
FRYPOT ASSEMBLY
CAN BE SPLIT POT
OR FULL POT OR IN
ANY COMBINATION
GAS CONNECTION ON FRYERS: FOR SINGLE FRYERS - 1/2" NPT FOR 2 OR MORE - 1" NPT
NOTE: BASKET LIFTS ARE OPTIONAL
INCHES (MM)
and H55
TOP VIEW
46.88 | OPTIONAL BASKET LIFT |
(1191) | IN RAISED POSITION |
| 31.25 |
| 2.75 | |
| (794) |
| ||
15.63 |
| (70) | ||
|
| |||
(397) |
|
|
| |
| CONTROL PANEL | 17.50 | ||
| (445) | |||
|
|
| ||
| 36.50 | 36.00 |
| |
DRAIN | (927) | (914) | 13.75 | |
HEIGHT |
|
| (349) | |
|
|
| ||
10.26 | DOOR ASSEMBLY |
|
| |
(261) |
|
| ||
2 |
|
| ||
|
|
| ||
11.63 | (50) | 8.50 | 9.35 | |
FRONT GAS CONNECTION | (216) | (237) | ||
(275) | ||||
| W/QUICK CONNECT |
| QUICK CONNECT | |
| FRONT VIEW |
| ||
|
| COUPLER FOR FLEXIBLE | ||
|
|
| METAL CONNECTOR |
(OPTIONAL)
SIDE VIEW
47.10
(1196)
45.60
(1158) 55.75
(1416)
ELECTRICAL SUPPLY
FOR BASKET LIFTER
MODEL
ELECTRICAL PLUG
STANDARD GAS
CONNECTION & CORD SET FOR
High Efficiency
DIMENSIONS -- INCHES (mm)
MODEL | SHORTENING | OVERALL SIZE | DRAIN | NET |
|
| SHIPPING INFO |
| ||||||
NO. | CAPACITY |
|
|
| HEIGHT | WEIGHT |
|
|
|
|
|
| ||
HEIGHT | WIDTH | LENGTH | WEIGHT | CLASS | CUBE |
| DIMENSIONS |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
H55 | 50 lbs. (25 liters) | 45.6” | 15.63” | 31.50”* | 10.26” | 160 lbs. | 202 lbs. | 85 | 21.32 | H |
| W |
| L |
25 lbs. (12 liters) ea. side | (1158 mm) | (397 mm) | (799 mm) | (261 mm) | (73 kg) | (92 kg) |
|
| 46.50” |
| 22” |
| 36” | |
|
|
|
|
|
|
|
|
|
| (1181 mm) |
| (559 mm) |
| (914 mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*without basket lifts
POWER REQUIREMENTS:
MODEL NO. | NATURAL OR LP GAS | ELECTRICAL | EXPORT |
| INPUT RATING |
|
|
|
|
|
|
H55 | 80,000 BTU/hr. input | 200V - 250V | |
| (20,151 kcal) (23.4 kW) | 120V (1.0 AMP) | 50/60 Hz. |
|
| 220V (0.5 AMP) | 3.5 AMP |
|
|
|
|
40,000 BTU/hr. input | Basket Lift |
| |
| each side (10,075 kcal) | 120V (7.0 AMP) |
|
| (11.7 kW) | 220V (3.5 AMP) |
|
HOW TO SPECIFY -- EXAMPLE:
H55 | Control panel, solid state controller, |
| electronic ignition, melt cycle, sealed |
| ON/OFF switch |
Split pot with same features as full pot plus | |
| dual controls to operate each pot |
| independently |
SD | Stainless steel frypot and door |
| cabinet |
SC | Stainless steel frypot, door and cabinet |
NOTES:
Supply Voltage 120V 60Hz
120 VAC 5 ft. (1.5 m) grounded cord set provided.
Recommended minimum store supply pressure to be 6" W.C. for NAT Gas, and 11" W.C. for L.P. Check plumbing codes for proper supply line sizing to attain burner manifold pressure of 3.0" W.C. natural or 8.25" W.C. L.P. Incoming supply line should be
CLEARANCE INFORMATION
A minimum of 24" (610 mm) should be provided at the front of the unit for servicing and proper operation, and 6" (152 mm) between the sides and rear of the fryer to any combustible material.
Gas Fryers Model#___________
CSI Section 11400
8700 Line Avenue 71106 | Tel: | www.frymaster.com |
P. O. Box 51000 | Tel: | Bulletin No. |
Shreveport, LA | Fax: | Litho in U.S.A. ©Frymaster, L. L. C. |
|
| |
|
|
|
We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.