Frymaster H55-2 and H55, Frymaster, High Efficiency, DIMENSIONS -- INCHES mm, Power Requirements

Models: H55-2

1 2
Download 2 pages 30.63 Kb
Page 2
Image 2
and H55

High EfficiencyFrymaster®

H55

26.70

ELECTRICAL SUPPLY FOR (4) BATTERY

(678)

ELECTRICAL SUPPLY FOR (2) BATTERY

22.00

(559)

 

14.35

ELECTRICAL SUPPLY FOR (3) BATTERY DIMENSIONS -- INCHES (mm)POWER REQUIREMENTS: (365)

6.38 HOW TO SPECIFY -- EXAMPLE:

2.25 (162)

(57)

34.2531.50

(869)(799)

W/BASKET W/O BASKET 27

LIFTER LIFTER (675)

REAR GAS CONNECTION ON FRYERS

FRYPOT ASSEMBLY

CAN BE SPLIT POT

OR FULL POT OR IN

ANY COMBINATION

GAS CONNECTION ON FRYERS: FOR SINGLE FRYERS - 1/2" NPT FOR 2 OR MORE - 1" NPT

NOTE: BASKET LIFTS ARE OPTIONAL

INCHES (MM)

and H55

TOP VIEW

46.88

OPTIONAL BASKET LIFT

(1191)

IN RAISED POSITION

-2

 

31.25

 

2.75

 

(794)

 

15.63

 

(70)

 

 

(397)

 

 

 

 

CONTROL PANEL

17.50

 

(445)

 

 

 

 

36.50

36.00

 

DRAIN

(927)

(914)

13.75

HEIGHT

 

 

(349)

 

 

 

10.26

DOOR ASSEMBLY

 

 

(261)

 

 

2

 

 

 

 

 

11.63

(50)

8.50

9.35

FRONT GAS CONNECTION

(216)

(237)

(275)

 

W/QUICK CONNECT

 

QUICK CONNECT

 

FRONT VIEW

 

 

 

COUPLER FOR FLEXIBLE

 

 

 

METAL CONNECTOR

(OPTIONAL)

SIDE VIEW

47.10

(1196)

45.60

(1158) 55.75

(1416)

ELECTRICAL SUPPLY

FOR BASKET LIFTER

MODEL

ELECTRICAL PLUG

STANDARD GAS

CONNECTION & CORD SET FOR NON-BASKET LIFTER MODEL (SEE TOP VIEW)

High Efficiency

DIMENSIONS -- INCHES (mm)

MODEL

SHORTENING

OVERALL SIZE

DRAIN

NET

 

 

SHIPPING INFO

 

NO.

CAPACITY

 

 

 

HEIGHT

WEIGHT

 

 

 

 

 

 

HEIGHT

WIDTH

LENGTH

WEIGHT

CLASS

CUBE

 

DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H55

50 lbs. (25 liters)

45.6”

15.63”

31.50”*

10.26”

160 lbs.

202 lbs.

85

21.32

H

 

W

 

L

H55-2

25 lbs. (12 liters) ea. side

(1158 mm)

(397 mm)

(799 mm)

(261 mm)

(73 kg)

(92 kg)

 

 

46.50”

 

22”

 

36”

 

 

 

 

 

 

 

 

 

 

(1181 mm)

 

(559 mm)

 

(914 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*without basket lifts

POWER REQUIREMENTS:

MODEL NO.

NATURAL OR LP GAS

ELECTRICAL

EXPORT

 

INPUT RATING

 

 

 

 

 

 

H55

80,000 BTU/hr. input

Non-basket lift

200V - 250V

 

(20,151 kcal) (23.4 kW)

120V (1.0 AMP)

50/60 Hz.

 

 

220V (0.5 AMP)

3.5 AMP

 

 

 

 

H55-2

40,000 BTU/hr. input

Basket Lift

 

 

each side (10,075 kcal)

120V (7.0 AMP)

 

 

(11.7 kW)

220V (3.5 AMP)

 

HOW TO SPECIFY -- EXAMPLE:

H55

Control panel, solid state controller,

 

electronic ignition, melt cycle, sealed

 

ON/OFF switch

H55-2

Split pot with same features as full pot plus

 

dual controls to operate each pot

 

independently

SD

Stainless steel frypot and door -- enamel

 

cabinet

SC

Stainless steel frypot, door and cabinet

NOTES:

Supply Voltage 120V 60Hz

120 VAC 5 ft. (1.5 m) grounded cord set provided.

Recommended minimum store supply pressure to be 6" W.C. for NAT Gas, and 11" W.C. for L.P. Check plumbing codes for proper supply line sizing to attain burner manifold pressure of 3.0" W.C. natural or 8.25" W.C. L.P. Incoming supply line should be 1-1/2". Should flexible gas line be used, it must be AGA approved, commercial type and sized per the gas line size in above drawing.

CLEARANCE INFORMATION

A minimum of 24" (610 mm) should be provided at the front of the unit for servicing and proper operation, and 6" (152 mm) between the sides and rear of the fryer to any combustible material.

Gas Fryers Model#___________

CSI Section 11400

8700 Line Avenue 71106

Tel: 318-865-1711

www.frymaster.com

P. O. Box 51000 71135-1000

Tel: 1-800-221-4583

Bulletin No. 818-0499 9/07

Shreveport, LA

Fax: 318-868-5987

Litho in U.S.A. ©Frymaster, L. L. C.

 

E-mail: info@frymaster.com

 

 

 

 

We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

Page 2
Image 2
Frymaster H55-2 and H55, Frymaster, High Efficiency, DIMENSIONS -- INCHES mm, Power Requirements, Clearance Information