Image 2
E4 Electric
45.3
[1149]

dimensionsFrymaster®

E4 Electric

TOP VIEW

15.6 power requirements [397] CLEARANCE INFORMATION

36.6

[929]

31.0

[786]

25.9

[657]

8.3

[212]

3.7

[95] CORDSET how to specifyManual background LOCATION Manual background

14.1

[358]Manual background

CORDSET

LOCATION

Fryers Model #_______________

CSI Section 11400

FRONT VIEWSIDE VIEWBACK VIEW

 

 

dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

model no.

 

 

overall size (cm)

 

 

net

Drain

 

 

shipping information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

weight

height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

height

 

width

 

length

 

 

weight

class

 

cu. ft.

 

dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RE14/17/22

 

45.30”

 

 

15.6*”

 

31.0”

 

 

150 lbs.

11.8”

190 lbs.

85

 

21.31

 

H

 

W

 

L

 

 

 

 

 

 

 

(1149 mm)

(397 mm)

 

(786 mm)

 

 

(68 kg)

(299 mm)

(86 kg)

 

 

 

 

46.50”

 

22”

 

36”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1181 mm)

 

(559 mm)

 

(914 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*without basket lifts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES

 

 

 

 

 

 

model

 

oil

 

input

 

 

 

 

 

 

nominal amps per line

 

 

 

 

 

CORD is provided on 3 phase units

 

 

number

capacity

 

Kw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with exception of items in red (see

 

 

 

 

(min.-max.)

 

 

 

 

208v

 

240v

 

 

480v

220/380v

 

230/400v

 

240/415v

 

 

 

 

 

 

 

 

 

 

 

 

3 phase

3 phase

 

 

3 phase

3 phase

 

3 phase

 

3 phase

 

chart on left).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3 wire)**

(3 wire)**

 

(3 wire)**

(4 wire)**

 

(4 wire)**

 

(4 wire)**

 

 

 

 

 

 

 

 

 

 

RE14

40-50 lbs.

14

 

 

39

 

34

 

 

17

 

22

 

21

 

20

 

 

Plug is optional on units shipping

 

 

 

 

(20-25 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with cord; Canada is an exception

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RE14-2

20-25 lbs.

7

 

 

39

 

34

 

 

17

 

22

 

21

 

20

 

 

and cords, where available, must

 

 

 

 

(10-12 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

have a plug attached.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RE17

40-50 lbs.

17

 

 

48

 

41

 

 

21

 

26

 

25

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

(20-25 liters)

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single phase units must be field

 

 

RE17-2

20-25 lbs.

 

8.5 ea.

 

48

 

41

 

 

21

 

26

 

25

 

24

 

 

wired. No cord or plug provided.

 

 

 

 

(10-12 liters)

 

side

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check electrical codes for proper

 

 

RE22

40-50 lbs.

22

 

 

61

 

53

 

 

27

 

34

 

32

 

31

 

 

supply line sizing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(20-25 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CE Voltage: 230/400/50/3

 

 

RE22-2

20-25 lbs.

11

 

 

61

 

53

 

 

27

 

34

 

32

 

31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(10-12 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLEARANCE INFORMATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**plus ground wire

For electrical connections, use an approved, flexible, metallic or rubber covered,

 

 

 

A minimum of 24” (610 mm) should

 

 

 

 

 

 

electrical cable and plug with copper wire only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be provided at the front of the unit

 

 

 

No cord or plug available per UL197-9.

 

 

 

Cord and plug optional.

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

how to specify

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for servicing and proper operation,

 

 

 

 

 

 

 

 

 

 

SD

Stainless steel pot, door , enamel cabinet

 

6” (152 mm) between the sides and

 

 

RE14

Full pot, solid state controls

 

 

 

 

 

 

 

 

rear of the fryer to any combustible

 

 

RE14-2

Split pot, solid state controls

 

 

SC

Stainless steel pot, door and cabinet

 

 

 

RE17

Full pot, solid state controls

 

 

 

 

 

 

 

 

 

 

 

 

 

material.

 

 

 

 

 

 

RE17-2

Split pot, solid state controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RE22

Full pot, solid state controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RE22-2

Split pot, solid state controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8700 Line Avenue

 

 

 

Tel: 318-865-1711

 

 

 

 

www.frymaster.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shreveport, LA 71106-6800

 

 

Tel: 1-800-221-4583

 

 

 

 

Bulletin No. 818-0468 11/07

 

 

 

 

 

 

 

 

 

 

USA

 

 

 

 

 

Fax: 318-868-5987

 

 

 

 

Litho in U.S.A. ©Frymaster, LLC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-mail: info@frymaster.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

Page 2
Image 2
Frymaster RE22-2, RE14-2 E4 Electric, Frymaster, dimensions, power requirements, Clearance Information, how to specify