HHT-145_OM.qxd 11/21/06 5:42 PM Page 4

OPERATION (CONTINUED)

°The filter status display turns on. (Note: The 1st segment is always filled in. Additional segments will fill in as the filter gets dirty.)

°The “filters” and “UV Bulb” lights will be green. (Note: if they are red then the filters must be cleaned or UV bulbs replaced.)

Changing the Cleaning Power Setting:

This model has 12 air cleaning settings for specialized cleaning capability. To increase the cleaning power, press the (+) button and to decrease the cleaning power, press the (–) button. The cleaning power display “segments” will increase when power is increased and vice versa.

Use a higher setting if you want to clean your room at a higher rate and use a lower setting for quieter operation.

Ionizer, UV and Oscillation Options:

Fig. 4

Press the ionizer ( ), UV ( ), or oscillate ( ) buttons to turn

these functions on or off. The ionizer button will be back-lit to indicate ionization is taking place. The UV button will be back-lit and the blue UV indicator light will illuminate when the UV feature is on. (Note: UV bulbs are inside the product and the UV light cannot be seen.) The oscillate button will be back-lit and the unit will oscillate when the oscillation feature is on.

Note: If you have asthma symptoms or other breathing disorders that can be triggered by the presence of an ionizer, we recommend that you do not activate the ionization feature.

Timer Operation:

Once the air purifier it turned on, it can be programmed to turn off automatically after a set amount of time (up to 18 hours).

Press the timer on\off button ( ). The default time of “9 hr” will appear in the timer display (Fig. 4).

If you want to increase or decrease the amount of time in which the product will shut off, press the timer (+) or (–) buttons.

To turn off the timer mode, just press the timer on\off button ( ).

Note: Removing the rear grille or turning off the unit will cancel the timer operation.

Filter Clean Indicator:

Fig. 5

The HEPA Type filters and pre-filter should be cleaned about every 3 months depending on use. The Filter Status display shows the approximate time left until the filters need to be cleaned.

When the Filters need to be cleaned, all of the Filter Status segments will be filled in and the Filters button LED will change from green to red (Fig. 5).

Clean the HEPA Type filters and pre-filter (see Cleaning instructions below) and then press and hold the Filters button for 5 seconds or until the light changes from Red to Green. The filter status bar will revert back to showing only one bar.

Page 4
Image 4
FujiFilm HHT145 Changing the Cleaning Power Setting, Ionizer, UV and Oscillation Options, Timer Operation