Temperature and Humidity Range

OPERATING TIPS

Temperature and Humidity Range

 

 

Cooling and Dry Mode

 

 

 

Indoor temperature

Maximum

95°F DB / 71°F WB

 

 

 

 

Minimum

64°F DB / 55°F WB

 

 

 

Outdoor temperature

Maximum

115°F DB

 

 

 

 

Minimum

32°F DB

Indoor humidity

Outdoor

About 80% or less

 

Temperature

If the unit is used for long periods under high-humidity conditions,

 

68°F or above

condensation may form on the surface of the indoor unit, and drip onto the

 

 

floor or other objects underneath.

 

 

 

 

Outdoor

About 50% or less

 

Temperature

If the unit is used for long periods under high-humidity conditions,

 

below 68°F

condensation may form on the surface of the indoor unit, and drip onto the

 

 

floor or other objects underneath.

 

 

 

DB : Dry Bulb Temperature

 

WB : Wet Bulb Temperature

 

÷If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

÷Do not use this unit for any purposes other than the Cooling, and Dehumidifying, and air-circulation of rooms in ordinary dwellings.