ADJUSTING THE DIRECTION OF AIR CIRCULATION

ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit's AIR FLOW DIRECTION button. Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.

Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.

Vertical Air Direction Adjustment

Press the AIR FLOW DIRECTION button (Fig. 6 ).

Each time the button is pressed, the air direction range will change as follows:

 

 

 

 

 

 

 

1

 

2

3

Cooling/

1

2

3

(6)NOTE

 

 

 

 

 

 

Dry mode

 

 

 

 

 

 

 

 

 

 

 

 

 

4

5

6

7

Fan mode

3

2

1

7

6

5

4

 

 

 

÷Use the air direction adjustments within the ranges shown above.

÷The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.

During Cooling/Dry mode: Horizontal flow 1

During Fan mode:

Downward flow 6

During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal 1; the air direction cannot be adjusted during this period.

NOTE

You can select the air direction 1, 2 , 3 , or 6 (downward) by pressing the AIR FLOW DIRECTION button.

Use the air direction 6 when you want to cool yourself for a while after taking a bath or shower, or after coming back home in summer months.

But, for prevention of condensation on the louver, the air direction 6 is auto- matically released after 30 minutes and turned to the air direction 3.

Right-Left Adjustment

Adjust the Right-Left Louvers

÷Move the Right-Left Louvers to adjust air flow in the direction you prefer.

Vertical Air Direction Adjustment CAUTION

÷Never place fingers or foreign objects inside the outlet ports, since the internal fan operates at high speed and could cause personal injury.

Always use the remote control unit's AIR FLOW DIRECTION button to adjust the vertical airflow louvers. Attempt- ing to move them manually could re- sult in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.

When used in a room with infants, chil- dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.