Supplement for Embedded MegaRAID SATA Users Guide

¾“4.9.2 Checking Array Controller Status” (page 98)

When using driver version of V10.xx or later, As for “4.9.2 Checking Array Controller Status” on page 98, include the information as follows;

Item

Category

Description

 

BIOS version

Version number of the expansion ROM BIOS for the

Adapter

 

array controller.

BIOS build time

BIOS build time of the expansion ROM BIOS for the

 

 

 

array controller.

¾“5.1.1 Message and Error Handling” (page 108)

POST messages and handling of the “5.1.1 Message and Error Handling” on page 108 is partially modified as follows;

 

Description

 

Detecting a logical drive being rebuilt

 

 

 

 

 

PORT x is Rebuilding State

 

 

 

 

 

 

WARNING : Array(s) in Degraded Mode!!!

 

 

 

Message

 

XX Virtual drive(s) Configured.

 

 

 

 

 

Array#

Mode

Stripe Size

No Of Stripes DriveSize

Status

 

 

 

00

RAID 1

64KB

02

XXXXXXMB

 

 

 

Degraded

 

 

 

 

 

 

 

The hard disc x connected to the port x is being rebuilt, and the logical drive is

 

Meaning

 

critical (degraded).

 

 

 

 

 

To start up SATA Setup Utility, press the [Enter] key or the [Ctrl]+[M]keys.

 

 

 

 

 

 

To pass POST, press any other key.

 

 

 

 

 

For expansion ROM BIOS A.05.09061342R:

 

 

 

 

 

 

 

 

POST halts waiting for key-in.

 

 

 

Action

 

To pass POST and invoke OS, press any key other than the [Enter] key or the

 

 

[Ctrl]+[M]keys.

 

 

 

 

 

 

For expantion ROM BIOS A.06.05071459R:

 

 

 

 

No action is required.

 

 

 