Supplement for Embedded MegaRAID SATA User’s Guide
Description Not detecting hard disks and unmatched insert locations
The displayed message is different according to the situation. [Message 1]
WARNING!
BIOS detected configured disks w. some drive(s) missing, pls power off the system, remove the drive from port:XX
and reinsert it in another slot.
Press any key to continue.
(*Press any key, and the following message appears.)
|
|
| If you proceed, you'll lose this configuration. |
|
|
| Press any key to continue. |
| Message |
|
|
|
|
| [Message 2] |
|
|
| Missing Drive reassigned to Port XX |
|
|
| Or, |
|
|
| Missing Drive cannot be relocated |
|
|
| PD(s) reassigned to different slot(s) because originally configured slot(s) have |
|
|
| different PD(s). |
|
|
| If you believe this is not a desired behavior, pls. power off the system and return the |
|
|
| PD(s) to their original slots to restore the previous configuration. |
|
|
| Otherwise, press any key to accept the resolved configuration |
|
|
| Press any key to continue. |
|
|
| The hard disk connecting to the port XX was connected to the other port at the last |
|
|
| startup. The hard disk connecting to the port XX last time is not found. |
| Meaning |
| In case of [message 1], The configuration information will be cleared by pressing |
|
| any key to continue. | |
|
|
| |
|
|
| In case of [message 2], The configuration information will be reconstructed by |
|
|
| pressing any key to continue, but consistency of configuration information is not |
|
|
| supported. |
|
|
| Contact an office listed in the “Contact Information” of “Start Guide”. |
| Action |
| Configuration information of the logical drives is not changed when turning off or |
|
|
| restarting the server while this message is displayed waiting for |
12 / 13