MB3891

(Ta = +25 °C, VBAT1 to VBAT4 = VCC-VSIM = 3.6 V)

Parameter

Symbol

Pin No.

Conditions

 

Value

 

Unit

 

 

 

Min.

Typ.

Max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output voltage

VO

21

10 A > V-BACKUP

2.000

2.100

2.200

V

 

> −250 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line regulation

Line

21

3.1 V < VBAT2 < 5.5 V

10

mV

 

 

 

 

 

 

 

 

 

 

Load regulation

Load

21

10 A > V-BACKUP

30

mV

 

> −250 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ripple rejection

 

 

 

 

 

 

 

 

ΔVBAT2/

R.R

21

f = 217 Hz

25

dB

LDO6

ΔV-BACKUP

 

 

 

 

 

 

 

(V-BACKUP)

GND current at

IGND

19

V-BACKUP > −10 A

10

A

 

low load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND current at

IGND

19

V-BACKUP = −250 A

50

A

 

max. load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output noise volt.

VNOVL

21

f = 10 Hz to 1 MHz,

500

V

 

(RMS)

V-BACKUP = 1 F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reverse current

IRC

21

VBAT2 = 0 V,

100

nA

 

V-BACKUP = 3.0 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output voltage

VO

24

0 A > REF-OUT > −50 A

1.200

1.225

1.250

V

 

 

 

 

 

 

 

 

 

 

Line regulation

Line

24

3.1 V < VBAT2 < 5.5 V

10

mV

 

 

 

 

 

 

 

 

 

 

Load regulation

Load

24

0 A > REF-OUT > −50 A

6

mV

 

 

 

 

 

 

 

 

 

REF-OUT

Ripple rejection

 

 

 

 

 

 

 

 

ΔVBAT2/

R.R

24

f = 217 Hz

50

dB

 

ΔREF-OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output noise volt.

VNOVL

24

f = 10 Hz to 1 MHz,

250

V

 

(RMS)

REF-OUT = 27 nF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VO

29

50 A > VSIMOUT > −10 mA,

4.600

5.000

5.400

V

 

Output voltage

 

 

SIMPROG = “H”

 

 

 

 

 

 

 

 

 

 

 

 

VSIMOUT

VO

29

50 A > VSIMOUT > −10 mA,

2.760

3.000

3.240

V

 

chargepump

 

SIMPROG = “L”

 

 

 

 

 

 

 

 

Line regulation

Line

29

3.1 V < VCC-VSIM < 5.5 V

50

mV

 

 

 

 

 

 

 

 

 

 

Load regulation

Load

29

50 A > VSIMOUT > −10 mA

100

mV

 

 

 

 

 

 

 

 

 

(Continued)

10

Page 10
Image 10
Fujitsu MB3891 manual ΔVBAT2, LDO6 ΔV-BACKUP Backup, RMS Backup = 1 ∝F, Δref-Out, Rms, Simprog = H Vsimout, Simprog = L