MB3891

(Ta = +25 °C, VBAT1 to VBAT4 = VCC-VSIM = 3.6 V)

 

Parameter

Symbol

Pin No.

Conditions

 

Value

 

Unit

 

 

 

 

 

Min.

Typ.

Max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output voltage

VO

3,

4

50 A > OUT3 > −100 mA

2.700

2.800

2.900

V

 

 

 

 

 

 

 

 

 

 

 

Line regulation

Line

3,

4

3.1 V < VBAT3 < 5.5 V

10

mV

 

 

 

 

 

 

 

 

 

 

 

Load regulation

Load

3,

4

50 A > OUT3 > −100 mA

30

mV

 

 

 

 

 

 

 

 

 

 

 

Ripple rejection

R.R

3,

4

f = 217 Hz

45

dB

 

ΔVBAT3/ΔOUT3

LDO3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dropout voltage

VDO

3,

4

OUT3 = −100 mA

250

mV

(OUT3)

 

 

 

 

 

 

 

 

 

 

 

GND current at low load

IGND

5

 

OUT3 > −1 mA

30

A

 

 

 

 

 

 

 

 

 

 

 

GND current at max.

IGND

5

 

OUT3 = −100 mA

2

mA

 

load

 

 

 

 

 

 

 

 

 

 

 

Output noise volt. (RMS)

VNOVL

3,

4

f = 10 Hz to 1 MHz,

350

V

 

OUT3 = 1 F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VO

40,

41

50 A > OUT4 > −100 mA,

2.700

2.800

2.900

V

 

Output voltage

CONT4 = “L”

 

 

 

 

 

 

 

 

 

 

VO

40,

41

50 A > OUT4 > −100 mA,

2.400

2.500

2.600

V

 

 

 

 

CONT4 = “H”

 

 

 

 

 

 

 

 

 

 

 

Line regulation

Line

40,

41

3.1 V < VBAT4 < 5.5 V

10

mV

 

 

 

 

 

 

 

 

 

 

 

Load regulation

Load

40,

41

50 A > OUT4 > −100 mA

30

mV

LDO4

 

 

 

 

 

 

 

 

 

Ripple rejection

R.R

40,

41

f = 217 Hz

45

dB

(OUT4)

ΔVBAT4 - OUT4/ΔOUT4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dropout voltage

VDO

40,

41

OUT4 = −100 mA

250

mV

 

 

 

 

 

 

 

 

 

 

GND current at low load

IGND

39

OUT4 > −1 mA

30

A

 

 

 

 

 

 

 

 

 

 

 

GND current at max.

IGND

39

OUT4 = −100 mA

2

mA

 

load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output noise volt. (RMS)

VNOVL

40,

41

f = 10 Hz to 1 MHz,

500

V

 

OUT4 = 1 F

 

 

 

 

 

 

 

 

 

 

Output voltage

VO

58

50 A > OUT5 > −50 mA

2.700

2.800

2.900

V

 

 

 

 

 

 

 

 

 

 

Line regulation

Line

58

3.1 V < VBAT3 < 5.5 V

10

mV

 

 

 

 

 

 

 

 

 

 

Load regulation

Load

58

50 A > OUT5 > −50 mA

30

mV

 

 

 

 

 

 

 

 

 

 

 

Ripple rejection

R.R

58

f = 217 Hz

45

dB

 

ΔVBAT3/ΔOUT5

LDO5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dropout voltage

VDO

58

OUT5 = −50 mA

250

mV

(OUT5)

 

 

 

 

 

 

 

 

 

 

GND current at low load

IGND

59

OUT5 > −500 A

20

A

 

 

 

 

 

 

 

 

 

 

 

GND current at max.

IGND

59

OUT5 = −50 mA

1

mA

 

load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output noise volt. (RMS)

VNOVL

58

f = 10 Hz to 1 MHz,

350

V

 

OUT5 = 1 F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Continued)

9

Page 9
Image 9
Fujitsu MB3891 manual Parameter Symbol Pin No Conditions Value Unit Min