Fujitsu manual MCE3064SS, MCF3064SS, MCE3130SS Magneto-Optical Disk Drives, Installation Guide

Models: MCF3064SS

1 2
Download 2 pages 17.92 Kb
Page 1
Image 1
MCE3064SS, MCF3064SS, MCE3130SS Magneto-Optical Disk Drives

MCE3064SS, MCF3064SS, MCE3130SS Magneto-Optical Disk Drives

Installation Guide

Installationsanleitung

Guide d'installation

This guide is prepared to instruct the user on the switch and jumper settings in the MCE3064SS/MCF3064SS/MCE3130SS when you install your MCE3064SS/MCF3064SS/MCE3130SS.

Note; Factory default settings are marked with .

Layout of PCA

SCSI ID Setting

 

Table 1

 

SCSI ID

SW1-01

SW1-02

SW1-03

 

0

Off

 

Off

Off

 

1

 

Off

 

Off

On

 

2

 

Off

 

On

Off

 

3

 

Off

 

On

On

 

4

 

On

 

Off

Off

 

5

 

On

 

Off

On

 

6

 

On

 

On

Off

 

7

 

On

 

On

On

SW1 AND CNH2 SETTINGS

Switch 1 sets the SCSI ID and some drive functions and CNH2 sets additional drive functions.

CNH2 (EXTERNAL SWITCH

SETTING)

Pin#

Function

Open

Short

1

Cartridge-in detection

2

SCSI ID 4

3

LED source (+5 V)

4

SCSI ID2

5

LED source (–)

6

SCSI ID1

7

Signal to eject cartridge

8

Ground

9

Device type mode

Fixed disk

MO

10

SCAM mode

Disabled

Enabled

11

Write verify mode

Enabled

Disabled

12

Ground

13

Macintosh mode

Disabled

Enabled

14

SCSI type 0

SCSI 2

SCSI 1

15

Terminating resister mode

Disabled

Enabled

16

Ground

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

OPERATOR PANEL

TTL-IC

0V

SW1

Key#

Function

Key on

 

Key off

 

01

 

————

————

02

SCSI ID (see table 1 above)

03

 

 

 

 

04

SCSI data bus parity check

Enabled

Disabled

 

05

Write cache mode

Enabled

 

Disabled

06

Device type mode

MO

Fixed Disk

 

Note: The cable length must not exceed 30cm.

Device Driver

You need to install Fujitsu's device driver to avoid the 2KB sector problem in Windows9x and the OS-timeout-problem in Windows9x and NT3.51/4.0.

MCE3064SS/MCF3064SS/MCE3130SS HANDLING AND MAINTENANCE

07

Spindle automatic stop mode

Enabled

Disabled

08

Factory test (Not to be set by user)

Enabled

Disabled

CNH1 (TERMINATING POWER AND SCSI TERMINATION)

Terminal CNH1 uses shorting bars to set the power source and to enable or disable SCSI termination.

Orientation

The drive can be installed in one of three orientations; either PCA up or on either side edge.

Ejecting cartridge

Cartridges can be ejected by pressing the eject key or by a

Cleaning lens and media recommendation

Clean the lens on the drive head and the disk media once every three months. More frequent cleaning may be required in a dirty environment. Use the Fujitsu head cleaning kit and

Pin#

Function

Short

Open

1–2

Power supplied by

Supplied

Not

 

drive

 

supplied

3–4

Power supplied by

Supplied

Not

 

host controller

 

supplied

5–6

SCSI termination

Enabled

Disabled

Power supplied by

1–2 3–4

Drive

Short Open

Host controller

Open Short

Drive and Host

Short Short

controller

 

SCSI eject command. Never eject a cartridge mechanically except in an emergency.

WORLD WIDE WEB SITE

media cleaning kit. Head cleaning kits from other vendors will not work.

COPYRIGHT FUJITSU LIMITED
SEPT. 1999
C156-E117-02XA

 

 

 

 

 

 

 

 

 

 

 

 

enabled

 

Corporate

http://www.fujitsu.co.jp/

SINGAPORE

http://www.fujitsu-computers.com.sg/

 

USA

http://www.fcpa.com/

CANADA

http://www.fujitsu.ca/

 

EUROPE

http://www.fujitsu-europe.com/

AUSTRALIA

http://www.fujitsu.com.au/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1
Image 1
Fujitsu manual MCE3064SS, MCF3064SS, MCE3130SS Magneto-Optical Disk Drives, Installation Guide, Installationsanleitung