Fujitsu R410A Operating Tips, Heating Performance, Low Ambient Cooling, Hot start, Fan speed AUTO

Models: R410A

1 16
Download 16 pages 55.9 Kb
Page 13
Image 13
OPERATING TIPS

OPERATING TIPS

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

*Heating Performance

This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insufficient heating performance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.

Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.

Low Ambient Cooling

When the outdoor temperature drops, the outdoor unit’s fans may switch to Low Speed, or one of the fans may stop intermittently.

* Hot start

The indoor unit prevents cold drafts when heating opera- tion begins.

The indoor unit fan will not operate until the heat exchanger reaches the set temperature.

*When Indoor and Outdoor Tempera- ture are High

When both indoor and outdoor temperatures are high during use of the heating mode, the outdoor unit’s fan may stop at times.

Fan speed: AUTO

*Heating: The fan will stop when the temperature of the air issued from the indoor unit is low.

Cooling: As the room temperature approaches that of the

 

set temperature, the fan speed becomes slower.

Fan:

The fan runs at the low fan speed.

*Microcomputer-controlled Automatic Defrosting

When using the Heating mode under conditions of low outdoor temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating per- formance.

In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled

Automatic Defrosting function. During the defrost cycle,

the indoor fan will shutdown and *Heating Performance will be displayed on the remote controller. It will take anywhere from 4 to 15 minutes before the air conditioner starts up again.

About ECONOMY OPERATION

At the maximum output, ECONOMY OPERATION is approxi- mately 70% of normal air conditioner operation for cooling and heating.

When ECONOMY OPERATION is performed during the cooling mode, dehumidification is improved. This function is especially convenient when you want to remove the humidity in the room without significantly lowering the room temperature.

During ECONOMY OPERATION, the thermostat setting automatically changes according to the temperature to avoid Unnecessary cooling and heating for the most economical operation.

If the room is not cooled (or heated) well during economy operation, select normal operation.

During the monitor period in the AUTO mode, the air conditioner operation will not change to ECONOMY OPERATION even if ECONOMY OPERATION is selected by pressing the ECONOMY button.

Dual Remote Controllers (optional)

An additional remove controller can be added up to the maximum of two remote controllers. Either remote controller can control the air conditioner. However, the timer functions cannot be used at the slave unit.

Group Control

One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings.