OPERATING TIPS
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
*Heating Performance
•This air conditioner operates on the
•
Low Ambient Cooling
•When the outdoor temperature drops, the outdoor unit’s fans may switch to Low Speed, or one of the fans may stop intermittently.
* Hot start
The indoor unit prevents cold drafts when heating opera- tion begins.
The indoor unit fan will not operate until the heat exchanger reaches the set temperature.
*When Indoor and Outdoor Tempera- ture are High
•When both indoor and outdoor temperatures are high during use of the heating mode, the outdoor unit’s fan may stop at times.
Fan speed: AUTO
*Heating: The fan will stop when the temperature of the air issued from the indoor unit is low.
Cooling: As the room temperature approaches that of the
| set temperature, the fan speed becomes slower. |
Fan: | The fan runs at the low fan speed. |
*Microcomputer-controlled Automatic Defrosting
•When using the Heating mode under conditions of low outdoor temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating per- formance.
In order to prevent this kind of reduced performance, this unit is equipped with a
Automatic Defrosting function. During the defrost cycle,
the indoor fan will shutdown and will be displayed on the remote controller. It will take anywhere from 4 to 15 minutes before the air conditioner starts up again.
About ECONOMY OPERATION
At the maximum output, ECONOMY OPERATION is approxi- mately 70% of normal air conditioner operation for cooling and heating.
When ECONOMY OPERATION is performed during the cooling mode, dehumidification is improved. This function is especially convenient when you want to remove the humidity in the room without significantly lowering the room temperature.
During ECONOMY OPERATION, the thermostat setting automatically changes according to the temperature to avoid Unnecessary cooling and heating for the most economical operation.
•If the room is not cooled (or heated) well during economy operation, select normal operation.
•During the monitor period in the AUTO mode, the air conditioner operation will not change to ECONOMY OPERATION even if ECONOMY OPERATION is selected by pressing the ECONOMY button.
Dual Remote Controllers (optional)
An additional remove controller can be added up to the maximum of two remote controllers. Either remote controller can control the air conditioner. However, the timer functions cannot be used at the slave unit.
Group Control
One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings.
12