Fujitsu ROOM AIR CONDITIONER, ABU22, ABO22 To Stop Horizontal airflow Swing Operation

Models: ROOM AIR CONDITIONER ABU22 ABO22

1 18
Download 18 pages 36.75 Kb
Page 12
Image 12

SWING OPERATION

Begin air conditioner operation before performing this procedure

To select Vertical airflow SWING Operation

Press the AIR FLOW DIRECTION VERTICAL SWING button .

The SWING indicator light (VERTICAL SWING) (orange) will turn on.

In this mode, the UP/DOWN air direction flaps will swing automatically to direct the air flow both up and down.

SET SWING SET SWING

TIME TEST

ENERGYADJUST RUN ACL

SAVE

To Stop Vertical airflow SWING Operation

Press the AIR FLOW DIRECTION VERTICAL SWING button Example: When set to vertical swing once again.

The SWING indicator light (VERTICAL SWING) will turn off.

Airflow direction will return to the setting before swing was begun.

About Swing Operation

The range of swing is relative to the currently set airflow direction.

Air flow direction set

Range of swing

 

 

1

1 to 3

2

1 to 4

 

 

3

2 to 5

 

 

4

3 to 6

5

4 to 7

 

 

6

5 to 7

 

 

7

1 to 7 (All range)

 

 

Air direction range (See page 11, Fig. 8)

If the swing range is not as desired, use the remote con- trol unit’s AIR FLOW DIRECTION VERTICAL SET button to change the range of swing.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

During use of the Cooling and Dry modes, do not set the air UP/DOWN direction flaps, in the Heating range (5 to 7) for long periods of time, since water vapor may con- dense near the outlet louvers and drops of water may drip from the air conditioner.

To select Horizontal airflow SWING Operation

Press the AIR FLOW DIRECTION HORIZONTAL SWING button.

The SWING indicator light (HORIZONTAL SWING) (orange) will turn on.

In this mode, the RIGHT/LEFT air direction louvers will swing automatically to direct the airflow both right and left.

SET SWING SET SWING

TIME TEST

ENERGYADJUST RUN ACL

SAVE

To Stop Horizontal airflow SWING Operation

Example: When set to horizontal swing

Press the AIR FLOW DIRECTION HORIZONTAL SWING button once again.

The SWING indicator light (HORIZONTAL SWING) will turn off.

Airflow direction will return to the setting before swing was begun.

About Swing Operation

The range of swing is relative to the currently set airflow direction.

Air flow direction set

Range of swing

1

1 to 5 (All range)

 

 

2

1 to 3

3

2 to 4

 

 

4

3 to 5

 

 

5

1 to 5 (All range)

 

 

Air direction range (See page 11, Fig. 9)

If the swing range is not as desired, use the remote con- trol unit’s AIR FLOW DIRECTION HORIZONTAL SET but- ton to change the range of swing.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

En-12

Page 12
Image 12
Fujitsu ROOM AIR CONDITIONER, ABU22, ABO22 To Stop Horizontal airflow Swing Operation, About Swing Operation

ROOM AIR CONDITIONER, ABU22, ABO22 specifications

The Fujitsu ABO22 and ABU22 ROOM AIR CONDITIONERS represent the pinnacle of modern cooling technology, designed to provide efficient, reliable climate control for both residential and commercial spaces. These models are characterized by their combination of advanced features, energy efficiency, and user-friendly operation, making them ideal choices for consumers seeking comfort and performance.

One of the standout features of the Fujitsu ABO22 and ABU22 is their energy efficiency. Both models are equipped with inverter technology, which allows for variable speed operation. This technology adjusts the compressor speed based on the cooling demand, leading to significantly reduced energy consumption compared to traditional air conditioning units. This not only lowers electricity bills but also contributes to a more sustainable environment by minimizing carbon emissions.

In terms of cooling performance, these air conditioners provide rapid cooling capability, ensuring that spaces reach the desired temperature quickly. The units come with multi-stage filtration systems that effectively trap dust, allergens, and pollutants, improving indoor air quality. This is particularly beneficial for allergy sufferers and those with respiratory issues, as clean air is essential for overall health.

User convenience is a key consideration in the design of the ABO22 and ABU22. Both units feature intuitive remote control options, allowing users to easily set parameters and adjust settings from anywhere in the room. Additionally, the models offer programmable timers and modes, including sleep mode and eco-mode, which further enhance comfort and efficiency.

Quiet operation is another characteristic of the Fujitsu ABO22 and ABU22. These air conditioners are designed to operate at lower noise levels, allowing users to enjoy a peaceful environment whether they are working, sleeping, or entertaining. This is particularly important in residential settings where noise can be a significant concern.

Moreover, the compact design of these units ensures easy installation and versatility, fitting seamlessly into various room layouts. With a sleek and modern aesthetic, they can complement different interior styles, making them a fashionable addition to any space.

Overall, the Fujitsu ABO22 and ABU22 ROOM AIR CONDITIONERS stand out for their energy efficiency, advanced air purification technologies, quiet operation, and user-friendly features, making them an excellent investment for enhanced indoor comfort. Whether for home or business, these air conditioners promise reliable and effective temperature control year-round.