L i f e B o o k C S e r i e s N o t e b o o k B I O S

Table 5: Fields, Options and Defaults for the Port Configuration Submenu of the Advanced Menu

Menu Field

Options

Default

Description

 

 

 

 

I/O Address:

400 - 43F

[400 - 43F]

Allows user to set the infrared port base I/O address when

 

480 - 4BF

 

the Fast Infrared (FIR) port is Enabled.

 

500 - 53F

 

 

 

580 - 5BF

 

(Note that if there is a conflict between the port interrupts

 

 

 

or addresses, asterisks will appear adjacent to the affected

 

 

 

port names to alert you to the fact. In that case, make a

 

 

 

different selection.)

 

 

 

 

DMA Channel:

DMA 1

[DMA 3]

Select the direct memory access channel for fast infrared

 

DMA 3

 

(FIR).

 

 

 

 

Parallel Port:

Disabled

[Enabled]

Configures the parallel port using either no configuration

 

Enabled

 

(Disabled), a user defined configuration (Enabled), or by

 

Auto

 

allowing the BIOS or OS to choose the configuration

 

 

 

(Auto).

 

 

 

 

Mode:

Output Only

[Bi-directional]

When the parallel port is enabled this option is available

 

Bi-directional

 

allowing the user to set the mode for the parallel port. Bi-

 

ECP

 

directional allows two-way transfer of information

 

 

 

between your notebook and a connected parallel device.

 

 

 

Output Only (Half Duplex) allows information to be trans-

 

 

 

ferred in only one direction, from your notebook to the

 

 

 

printer or similar device. ECP Mode allows communication

 

 

 

with the ECP class of parallel I/O devices. Check your

 

 

 

device documentation for the proper setting.

 

 

 

 

I/O address:

378 - 37F

[378 - 37F]

Allows user to set the parallel port base I/O address when

 

278 - 27F

 

the parallel port is Enabled.

 

3BC - 3BF

 

 

 

 

 

 

Interrupt:

IRQ 5

[IRQ 7]

Allows user to set the parallel port interrupt when the par-

 

IRQ 7

 

allel port is Enabled.

 

 

 

 

14

Page 14
Image 14
Fujitsu Siemens Computers C2310 manual Menu Field, Options, Default, Description