Furman Sound IT-20 II manual Specifications

Models: IT-20 II

1 8
Download 8 pages 19.54 Kb
Page 8
Image 8
SPECIFICATIONS

SPECIFICATIONS

AC Current Output:

20 Amps (2400 watts at 60/120V)

Shutdown Voltage:

At 135-140 VAC

Inlets:

Heavy duty power cord with 20A three-pronged plug

Outlets:

12 rear (isolated), 2 front (GFCI) each rated at 20 amps

Spike Protection Modes:

Line to neutral, zero ground leakage

Spike Clamping Voltage:

188 Vpk @ 3,000 amps, 133 VAC RMS (Tested to UL-1449 6,000 Vpk @ 3,000 amps)

Response Time:

1nanosecond

Maximum Surge Current: 6,500 amps

Differential Noise Attenuation: 10dB @ 10kHz

40dB @ 100 kHz

100dB @ 10 MHz

Common Noise Attenuation:

Greater than 80 dB @ 20Hz to 20 KHz Greater than 40 dB @ 20Khz to MHz

Linear attenuation curve from 0.05-100 ohms line impedance

Turns Ratio:

1:1, windings separated with Faraday Shield

Transformer Regulation: 3% at full load

Power Consumption:

12watts for display and control circuits

Voltmeter Accuracy:

± 1V

Dimensions:

19” W x 5.25” H x 17” D, 80 lbs.

051206-C

Furman Sound, LLC

1690 Corporate Circle. Petaluma, California 94954-6919 USA Phone: 707-763-1010 Fax: 707-763-1310

Web: www.FurmanSound.com E-mail: info@furmansound.com