Furuno manual Specifications of CH-250, Range scales and Pulselength

Models: CH-250

1 4
Download 4 pages 8.76 Kb
Page 4
Image 4
By L/L or Echo position
NMEA 0183 Ver 1.5, 2.0 (IEC 61162-1)
DBS, DBT, DPT, GGA, GLL, HDG, HDM, MDA, MTW, RMA, RMC, VDR, VHW, VTG
SSTLL
English, Spanish, Danish, Portuguese, French, Norwegian, Italian, Swedish, Thai
12-24/32 VDC, 55 W
12/24-32 VDC, 55 W
(200 W while raising/lowering transducer)

SPECIFICATIONS OF CH-250

1. Range scales and Pulselength

 

 

 

 

 

 

 

 

 

 

150 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

 

 

 

 

Meters

10

20

40

60

80

120

160

200

250

300

400

500

600

800

1000

 

 

 

Unit

Feet

40

80

120

200

300

400

500

600

700

800

1000

1500

2000

2500

3500

 

 

 

Fathoms

10

20

40

60

80

100

120

140

160

200

250

300

400

500

600

 

 

 

 

P/B

10

20

40

60

80

100

120

140

160

200

250

300

400

500

700

 

 

 

Time to train full circle (s)￿ 7

7

7

7

7

10

12/13

14/16

16/20

18/24

22/32

26/40

30/48

38/64

46/81

 

 

 

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max scale depends on the system frequency. 1600 m (60 kHz), 1200 m (88 kHz), 1000 m (150 kHz). Training speed is subject to the system frequency and range scales. Two speeds on long range scales.

2.

Display Unit

10.4" TFT color LCD (VGA: 640 x 480 pixels)

3.

Color

8 or 16 colors

4.Display Mode

(1)Full Circle scan (2) Zoom (x 1.5) (3) Vertical scan

(4)Vertical Sounder (5) Full/Half Circle and Vertical scan

(6)Full Circle and History (7) Full Circle and Strata

(8)Full Circle and VideoPlotter

5.

Audio monitor

1000 Hz

6.

TX Output Power

0.8-1.2 kW

7.

Beamwidth (at -3 dB)

 

60 kHz:

15° (H) x 12° (V) 88 kHz: 11.5° (H) x 9.5° (V)

 

150 kHz:

6.5° (H) x 6.5° (V)

8.

Transducer Control

 

 

Tilt

 

0° to -180° at 3° or 6° steps (in vertical scan)

 

 

 

+5° to -90° at 1° steps (in full circle scan)

Training sector

Manual or automatic training at 6° or 12° steps in search sector 6°- 360°

Target Lock

9.Interface Input:

Output:

10.Language

EMC AND ENVIRONMENT (Complies with IEC 60945)

 

Display unit:

-15°C to +55°C

 

Water resistance

IEC IPX5, USCG CFR 46 (Display unit)

EQUIPMENT LIST

 

 

Standard

 

 

1.

Display Unit MU-100C

 

1 unit

2.

Control Unit CH-252

 

1 unit

3.

Hull Unit CH-254 (travel 400 mm) or CH-255 (travel 250 mm)

1 unit

4.

Transceiver unit CH-253

 

5.

Installation materials and spare parts

1 set

6.

Interface unit IF-8000 (Blackbox type only)

1 unit

Option

1.Remote controller CH-256

2.Rectifier RU-1746B-2

3.External speaker SC-05WR

4.1 m tall steel tank (06-007-1570), 1.8 m tall steel tank (SHJ-0001),

3.5m tall steel tank (06-007-1571), 1 m tall FRP tank (SHJ-0022),

1.8m tall FRP tank (06-007-1573), 1 m tall aluminum tank (OP10-5),

5.NMEA cable

MJ-A6SPF0012-050 (5 m), MJ-A6SPF0011-050 (5 m), MJ-A6SPF0012-100 (10 m), MJ-A6SPF0011-100 (10 m),

6.Motion sensor MS-100 or Clinometer BS-704

7.Interface unit IF-8000

Power Supply

Transceiver unit Hull unit

DISPLAY UNIT and CONTROL Unit

 

 

MU-100C and CH-252

5.7 kg, 12.6 lb

 

 

 

 

 

 

290

11.4"

 

9

11

 

 

 

 

 

HULL UNIT

 

 

CSH-254(Travel 400 mm)

 

43 kg, 94.8 lb

 

 

 

 

CSH-255(Travel 250 mm)

 

42 kg, 92.6 lb

 

 

 

 

 

138

8-M20 HEX BOLT

 

 

5.4"

 

 

 

 

 

 

131

5.2"

 

 

297

 

 

 

11.7"

 

 

5.9"

 

 

 

150

 

 

 

 

 

180

 

 

 

 

 

7.1"

 

 

18.7/24.6"

 

 

 

 

 

 

 

 

 

 

475/625

343

 

 

 

 

13.5"

 

 

 

 

 

 

 

 

17.7"

39/70/137"

 

 

 

 

450

m

 

 

10

0.4"

1.0/1.8/3.5

 

 

 

 

Travel

 

 

 

185

 

 

 

 

 

7.3"

 

 

 

 

TRANSCEIVER UNIT CH-2533.2 kg, 7.1 lb

76 3"￿

￿6

294

11.6"￿

 

-

250

9.8"￿

16.5￿

4

 

 

0.7"￿

 

 

 

18.7"￿

17"￿

17.9"￿

475

431

455

REMOTE CONTROLLER (OPTION) CH-256

24￿

0.3 kg

180

7.1"￿

 

 

 

 

 

 

 

 

0.7 lb

 

 

127 5.0"￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300 ￿11.8"

90 3.5" 210 8.3"

327 12.9"

 

 

 

357 14.1"

 

 

 

 

 

 

169

6.7"

 

Flush mount

 

 

 

206

8.1"

 

 

4.2 kg, 9.3 lb

86

3.4"

160

6.3"

 

 

 

 

 

 

 

 

 

320

12.6"

 

5.0"

 

 

 

 

153 6.0"

127

 

41￿

 

 

153 6.0"

 

 

 

 

 

 

 

 

 

 

1.6"

0.9"￿

334 13.2"

320 12.6"

 

 

 

 

 

2.1"￿

 

 

 

 

 

 

 

52

 

 

6- 7

 

 

 

 

 

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

FURUNO U.S.A., INC.

FURUNO DANMARK AS

Camas, Washington, U.S.A.

Hvidovre, Denmark

Phone: +1 360-834-9300 Telefax: +1 360-834-9400

Phone: +45 36 77 45 00 Telefax: +45

0406XN Printed in Japan

36 77 45 01

FURUNO (UK) LIMITED

FURUNO NORGE A/S

Denmead, Hampshire, U.K.

Ålesund, Norway

Phone: +44 2392-230303 Telefax: +44 2392-230101

Phone: +47 70 102950 Telefax: +47 70 127021

FURUNO FRANCE S.A.

FURUNO SVERIGE AB

Bordeaux-Mérignac, France

Västra Frölunda, Sweden

Phone: +33 5 56 13 48 00 Telefax: +33 5 56 13 48 01

Phone: +46 31-7098940 Telefax: +46 31-497093

FURUNO ESPANA S.A.

FURUNO SUOMI OY

Madrid, Spain

Helsinki, Finland

Phone: +34 91-725-90-88 Telefax: +34 91-725-98-97

Phone: +358 9 341 7570 Telefax: +358 9 3417 5716

Page 4
Image 4
Furuno manual Specifications of CH-250, Range scales and Pulselength