Furuno CH270 manual Motion Sensors, Inclinometers Longer Interconnect Cables

Models: CH270

1 13
Download 13 pages 26.82 Kb
Page 10
Image 10

Motion Sensors, Inclinometers and

Longer Interconnect Cables

This valuable accessory unit must be mounted correctly to obtain any benefit from it:

a)Select a mounting location that is dry and vibration free

b)The selected location should be as close to the sonar hoist unit as possible

c)Mount the unit level (only compensating for normal vessel trim)

d)Line the unit up "fore and aft" accurately

e)Mount the unit "right side up" only

If a longer interconnect cable assembly is required, the following options are available:

Part number

Description

MS1-CBL-15M

15 meter signal cable assembly

MS1-CBL-30M

30 meter signal cable assembly

MS1-CBL-50M

50 meter signal cable assembly

Note:

The MS100 compensates for any vessel pitching and rolling at sea. To properly set itself the motion sensor must be powered up while the vessel is in a stable condition. This step is easi- er to accomplish at the dock. Please get in the habit of powering up the entire CH270 system prior to departing from the dock. This one easy step will ensure proper operation of the MS100 and enhanced CH270 performance for the duration of the voyage.

Soundome Cover Removal and Replacement

To detach or replace the soundome cover assembly, remove the 8 stainless steel cross head cap screws.

Once the soundome has been filled with oil, keep it in a vertical position to prevent any internal seepage. If the soundome assembly has to be removed for repair or shipment, the oil must always be removed.You may wish to retain the soundome packing material for future use.