45
E/S Menu
Item
E/S SHIFT
E/S IR
E/S GAIN
E/S CLUTTER
E/S ADVANCE
E/S COL CURVE
(Response Color
Curve)
E/S DRAFT
Contents
Shifts the start depth of the display range and the maximum value is about
1000 m irrespective of the depth unit. The unit shift value is determined by
the range in use. See table below.
Turns the Interference Rejector on and off.
Controls the gain of the Echo Sounder picture.
Eliminates the noise appearing on the screen.
Adjusts the picture advancement speed. 1/1 is fastest, 1/8 is slowest.
This menu sets the balance between weak and strong echoes. In the LINEAR
position, output (echo strength displayed) varies proportionally with input
(actual echo strength). Select a higher setting to emphasize weak echoes.
Weak echoes are displayed in stronger echo colors as the number goes higher.
The standard setting is the LINEAR position.
Adjusts the draft of the own ship according to loading conditions.
Irrespective of the depth unit selection, the draft adjustment is available from
0 to 10 m in 0.5 m steps.
M FT FA P/B
220501010
3 40 100 20 20
4 50 100 25 25
5 50 200 40 40
6 100 200 50 50
7 100 300 50 50
1 10 25 5 5
20 60 10
40 120 20
80 240 40
120 360 60
160 480 80
240 720 120
320 960 160
M FT FA P/B
2
3
4
5
6
7
20
40
60
80
120
160
110
Depth unit may be selected on the SYSTEM Menu.
Selects the display range of the Echo Sounder from the table below.E/S RANGE