5.Select the appropriate data transmission rate from 4800 bps and 38.4 kbps for PC I/O, SNSR 1, SNSR 2, SNSR 3, LR, BCON (beacon receiver), EXTRA1 and EXTRA2, by pressing the [SFT] key. To select each item, press the [NEXT] key. To go backward, press the [NEXT] key while pressing the [SFT] key.

6.Press the [ENT] key to return to the SET I/O PORT sub-menu.

7.Press the [2] key to display the I/O FUCTION window.

[I/O FUNCTION]

PORT LR: EXT DISP + -

I/O FUNCTION window

8.Press the [SFT+/-] key to select EXT DISP or LR, depending on equipment connected.

EXT DISP: External display, such as radar, ECDIS

LR: Long range communication, such INMARSAT communication equipment

9.Press the [ENT] key to return to the SET I/O PORT sub-menu.

10.Press the [3] key to display the I/O PRIORITY window.

[I/O PRIORITY]

1 L/L COG SOG

2HDG

3 ROT

4 AIS

I/O PRIORITY window

11. Press the [1] key to display the L/L COG SOG window.

[L/L COG SOG]

 

 

SN1:

1

 

SN2: 2

SN3:

3

 

 

 

EX1 : 4

LR :

5

PC : 6

LAN:

7

DEFAULT: [CLR]

L/L/COG/SOG PRIORITY window