To connect the transducers which are not programmed, do as follows:

Note: The transducers of 53 - 65 kHz, 111 to 139 kHz and 171 - 183 kHz cannot be connected to the FCV-295 because of noise.

1.At the XDCR Setting dialog box, select "XDCR Select" and press the ENTER key. The following screen appears.

XDCR Type

Manual

2.Press T to select "Manual", and then press the ENTER key.

3.If a high frequency transducer is fitted, press T to select "HF Connection" and then press the ENTER key.

Connected

Not connected

4.Press S to select "Connected" and then press the ENTER key.

5.Press T to select "Freq" and then press the ENTER key.

---kHz

6.Press T or S to set the frequency of the transducer which is connected and then press the ENTER key.

7.Press T to select "Band width" and then press the ENTER key.

8.Press T or S to set the value for the bandwidth and then press the ENTER key. If the band- width is not entered manually, it is automatically set to 1/10 of the transducer frequency.

9.If a low frequency transducer is fitted, repeat steps 3 to 8. Note: Leave the "Tx Power" at "Auto".

10.Press and hold down the [ /BRILL] key to turn off the power.

3.3Speed/Water Temperature Sensor Calibration

If the optional speed and/or water temperature sensor is connected, set it up as follows:

1.Turn on the power and press the MENU key. The main menu and sub-menu appear.

2.Press T to select "System" and "Calib" and then press the ENTER key.

13

Page 22
Image 22