Furuno FCV-295 Thru-hull mount water temperature sensor T-02MSB, T-03MSB, 02MSB 03MSB

Models: FCV-295

1 32
Download 32 pages 44.16 Kb
Page 12
Image 12

Thru-hull mount water temperature sensor T-02MSB, T-03MSB

Select a suitable mounting location considering the following points:

Select a mid boat flat position. The sensor does not have to be installed perfectly perpendicu- lar; however, the location should not be such that the transducer may be damaged when the boat is dry-docked.

Locate away from equipment which gives off heat.

Locate away from drain pipes.

Select a location where vibration is minimal.

 

 

 

 

 

 

 

T-02MSB

 

 

 

 

 

 

 

 

 

 

T-03MSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor Holder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 m

Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 m

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Locknut

 

 

 

 

 

 

 

 

 

Locknut

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Washer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gasket

 

 

 

 

 

 

 

 

 

 

Locknut

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

φ21 mm

 

 

 

 

 

 

 

 

 

 

Washer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gasket

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

φ25 mm

 

 

 

 

 

 

 

 

 

M20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

 

 

 

 

 

 

Coat with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sealant.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coat with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sealant.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

φ42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plate thick-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting procedure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ness within

1. Drill a hole of 21 mm in diameter in

 

 

 

 

 

 

 

 

 

 

 

 

Holder Guide

 

 

25 mm

the mounting location.

 

 

 

Mounting procedure

2. Pass the sensor cable through the

1. Drill a hole of 25 mm in diameter in the mounting

hole.

 

 

 

 

 

 

 

 

 

 

 

 

location.

 

 

 

 

3. Pass gasket, washer and locknut

 

 

 

 

 

 

2. Coat holder guide with high quality sealant, and

onto cable in that order.

 

 

pass gasket, washer and locknut onto holder

4. Coat the sensor flange with high

 

 

 

 

guide in that order and then tighten the locknut.

quality sealant and then fasten the

 

 

3. Set the sensor holder to the holder guide from

sensor with the locknut.

 

 

inside the boat and then tighten the locknut.

(Torque: max. 59N·m)

 

 

4. Launch the boat to check for water leakage

5. Launch the boat to check for water

 

 

around the sensor.

leakage around the sensor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Assembling thru-hull water temperature sensor T-02MSB, T-03MSB