4. INSTALLATION
4-6

Receiver unit

All cables are gathered to the receiver unit. Connect cables at inside of the

receiver unit as shown below.

DSUB25P-DSUB25P-3M cable
(to Display unit)
DPYC-2.5
(to ship's battery)
RCV Board
08P3227
TTYCS-1Q
(to Navigator
or INS )
DPYC-1.5
(to External alarm)
Printer cable
(to Printer, NX-700B only)
Antenna cable
(to Antenna unit)
TB401
(+) TB402
(-) J402* J403
J401
1 2 3 4 5 6 1 2 3 4 5 6 7 8

Receiver unit, inside view

Use the following JIS cable (Japan Industrial Standard) or equivalent to connect

power source, INS and external alarm appropriately.

Conductor

S = 2.5 mm

φ = 2.01 mm

2

DPYC-2.5

Armor

Sheath

φ = 12.5 mm

Conductor
S = 1.5 mm
φ = 1.56 mm
2
DPYC-1.5
Armor
Sheath
φ =
11.7 mm
Conductor
S = 0.75 mm
φ = 1.11 mm
2
TTYCS-1Q (Four core twisted)
Armor
Shield
Sheath
φ = 11.3 mm

For printer, use the cable supplied with the printer.