Gaggenau AH 530-720 7’3”3,15- - 10’1”, 5’3”, height, 100480, 600min.24”, electricover cooker

Models: AH 530-720 AH 530-790

1 18
Download 18 pages 41.9 Kb
Page 15
Image 15
height

Flexible aluminium pipes, corrosion-protected

The duct units listed below are available

 

sheet metal pipes and exhaust air pipes whose

depending on the height of the ceiling:

 

material conforms to fire B1 in accordance with

Stainless steel-design ventilation duct:

 

DIN 4102 can be used. Exhaust air pipes should

 

LK 530-010 for ceiling heights of

 

 

have a nominal diameter of 6 ´ ´ / 150 mm.

 

 

7 ´´ 3 ´ ´ - 8 ´´ 6 ´ ´ / 2.20 - 2.66 m

Pay particular attention to ensuring that

LK 530-020 for ceiling heights of

 

 

– the exhaust air ducts and pipes are kept as short

8 ´´ 6 ´ ´ - 10 ´´ 1 ´ ´ / 2.66 - 3.15 m

Aluminium-design ventilation duct:

 

 

as possible

 

 

– the pipes are not laid at an acute angle, but as

LK 530-011 for ceiling heights of

 

 

7 ´´ 3 ´ ´ - 8 ´´ 6 ´ ´ / 2.20 - 2.66 m

bends and that they are inserted into the shaft at

LK 530-021 for ceiling heights of

 

 

an inclined upward angle and

 

 

8 ´´ 6 ´ ´ - 10 ´´ 1 ´ ´ / 2.66 - 3.15 m

 

– there are no cross-sectional constrictions in the

The dimensions above refer to a distance of 5 ´´ 3 ´ ´ /

upward direction (this reduces the volume flow).

1.60 m from the floor to the bottom edge of the

As standard, the blow-out opening of the wall hood

hood.

 

 

 

 

If required, individually sized ventilation ducts are

is in the upward direction.

To pass exhaust air through the outer wall, we

available at an extra charge.

 

 

The power connection must be placed behind the

recommend the use of our telescopic wall box

TM 150-045 (Ø 6 ´ ´ / 150 mm).

duct cover on the wall.

 

 

 

 

Note:

 

 

 

height

 

To prevent the ingress of water, e.g. condensate or

 

 

 

 

rain water from an uncovered exhaust air shaft, our

 

 

 

Hood

 

condensate separator RV 060-150 must be installed

 

100480

”)/(3”)/(18168157

-(24”1550-6005’1”)

heightCeiling

in the exhaust air line. The condensate separator

260

must still be acciessible after installation.

(101/4”)

 

 

 

(7’3”3,15- - 10’1”)

 

600min.(24”)

electricover cooker

700min.(27 gasovercooker

(5’3”)

 

550

 

”)

 

 

 

(2110/16”)

 

21/

 

 

 

 

 

 

1600

2,20

 

Fig. 18

 

 

 

 

 

 

 

 

 

15

Page 15
Image 15
Gaggenau AH 530-720, AH 530-790 manual 7’3”3,15- - 10’1”, 5’3”, height, 100480, 600min.24”, electricover cooker, 2110/16”